English
Language : 

FGSD12SR6003A Datasheet, PDF (18/41 Pages) List of Unclassifed Manufacturers – 3-14.4Vdc Input, 3A, 0.45-5.5Vdc Output
Delivering Next Generation Technology
Series
FGSD12SR6003*A
3-14.4Vdc Input, 3A, 0.45-5.5Vdc Output
for two’s complement representation of the mantissa,
with the 11th bit fixed at zero since only positive
numbers are valid.
During module manufacture, offset and gain
correction values are written into the non-volatile
memory of the module. The command
VIN_CAL_OFFSET can be used to read and/or write
the offset - two bytes consisting of a five-bit exponent
(fixed at -5) and a 11-bit mantissa in two’s
complement format. The allowed range for this offset
correction is -2 to 1.968V, and the resolution is
32mV. The command VIN_CAL_GAIN can be used
to read and/or write the gain correction - two bytes
consisting of a five-bit exponent (fixed at -8) and a
11-bit mantissa. The range of this correction factor is
-0.125V to +0.121V, with a resolution of 0.004V. The
corrected output voltage reading is then given by:
VIN (Final ) 
[VIN (Initial )  (1VIN _ CAL _ GAIN )]
 VIN _ CAL _ OFFSET
Reading the Status of the Module using the
PMBus
The module supports a number of status information
commands implemented in PMBus. However, not all
features are supported in these commands. A 1 in
the bit position indicates the fault that is flagged.
STATUS_BYTE: Returns one byte of information
with a summary of the most critical device faults.
Bit
Position
7
6
5
4
3
2
Flag
X
OFF
VOUT Overvoltage
IOUT Overcurrent
VIN Undervoltage
Temperature
Default
Value
0
0
0
0
0
0
1
CML (Comm. Memory Fault)
0
0
None of the above
0
Preliminary Data Sheet
STATUS_WORD: Returns two bytes of information
with a summary of the module’s fault/warning
conditions.
Low Byte
Bit
Position
7
Flag
X
Default
Value
0
6
OFF
0
5
VOUT Overvoltage
0
4
IOUT Overcurrent
0
3
VIN Undervoltage
0
2
Temperature
0
1
CML (Comm. Memory Fault) 0
0
None of the above
0
High Byte
Bit
Position
7
Flag
VOUT fault or warning
Default
Value
0
6
IOUT fault or warning
0
5
X
0
4
X
0
3 POWER_GOOD# (is negated) 0
2
X
0
1
X
0
0
X
0
STATUS_VOUT: Returns one byte of information
relating to the status of the module’s output voltage
related faults.
Bit
Position
7
6
5
4
3
2
1
0
Flag
VOUT OV Fault
X
X
VOUT UV Fault
X
X
X
X
Default
Value
0
0
0
0
0
0
0
0
STATUS_IOUT: Returns one byte of information
relating to the status of the module’s output voltage
related faults.
Bit
Position
7
6
5
4
3
2
1
0
Flag
IOUT OC Fault
X
IOUT OC Warning
X
X
X
X
X
Default
Value
0
0
0
0
0
0
0
0
Http://www.fdk.com
Page 18 of 41
Ver 1.6 May. 8, 2013