TABLE IIA. Electrical test requirements.
Test requirements
Interim electrical
parameters (see 4.2)
Final electrical
parameters (see 4.2)
Group A test
requirements (see 4.4)
Group C end-point electrical
parameters (see 4.4)
Group D end-point electrical
parameters (see 4.4)
Group E end-point electrical
parameters (see 4.4)
Subgroups
(in accordance with
MIL-STD-883, method
5005, table I)
Device
class M
---
1/ 1, 2, 3, 7,
8, 9
1, 2, 3, 4, 7,
8, 9, 10, 11
1, 2, 3
1, 2, 3
1, 7, 9
Subgroups
(in accordance with
MIL-PRF-38535, table III)
Device
class Q
Device
class V
---
1
1/ 1, 2, 3, 7,
8, 9
1, 2, 3, 4, 7,
8, 9, 10, 11
1, 2, 3
2/ 3/ 1, 2, 3, 7,
8, 9, 10, 11
1, 2, 3, 4, 7,
8, 9, 10, 11
3/ 1, 2, 3, 7,
8, 9, 10, 11
1, 2, 3
1, 2, 3
1, 7, 9
1, 7, 9
1/ PDA applies to subgroup 1.
2/ PDA applies to subgroups 1, 7, and deltas.
3/ Delta limits, as specified in table IIB, shall be required where specified, and the delta limits
shall be completed with reference to the zero hour electrical parameters.
TABLE IIB. Burn-in and operating life test, delta parameters (+25°C). 1/
Parameter 2/
Quiescent supply current
Input current low level
Input current high level
Output voltage low level
(VCC = 5.5 V, IOL = 24 mA)
Output voltage high level
(VCC = 5.5 V, IOH = -24 mA)
Symbol
ICCH, ICCL, ICCZ
IIL
IIH
VOL
Device
type
02
02
02
02
Delta limits
±300 nA
±20 nA
±20 nA
±0.04 V
VOH
02
±0.20 V
1/ This table is representation of what vendor CAGE F8859 has
experienced and is guaranteed and not meant to be construed
as a quality assurance requirement for any other vendor.
2/ These parameters shall be recorded before and after the required
burn-in and life tests to determined delta limits.
4.4.2 Group C inspection. The group C inspection end-point electrical parameters shall be as specified in table IIA herein.
4.4.2.1 Additional criteria for device class M. Steady-state life test conditions, method 1005 of MIL-STD-883:
a. Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of
MIL-STD-883.
b. TA = +125°C, minimum.
c. Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
STANDARD
MICROCIRCUIT DRAWING
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
A
REVISION LEVEL
H
5962-87758
SHEET
15