English
Language : 

TS55001 Datasheet, PDF (14/22 Pages) List of Unclassifed Manufacturers – High Efficiency Li-Ion Battery Charger
TS55001
Version 1.3
CONFIGURATION REGISTER (CONFIG2)
Address – 0x03h
DATA BIT
D7
D6
D5
D4
D3
FIELD NAME EOC[1:0]
V_TERM_45_50[2:0]
READ/WRITE R/W
R/W
R/W
R/W
R/W
D2
D1
V_TERM_50_60[2:0]
R/W
R/W
D0
R/W
FIELD NAME
BIT DEFINITION
EOC[1:0](1)
End of charge configuration
00 – 50 mA
01 – 100 mA
10 – 185 mA
11 – 370 mA
V_TERM_45_50[2:0](2)
Voltage Termination 45-50°C configuration
000 – 3.94 V
001 – 4.00 V
010 – 4.05 V
011 – 4.10 V
100 – 4.12 V
101 – 4.15 V
110 – 4.18 V
111 – Invalid Setting
V_TERM_50_60[2:0](2)
Voltage Termination 50-60°C configuration
000 – 3.94 V
001 – 4.00 V
010 – 4.05 V
011 – 4.10 V
100 – 4.12 V
101 – 4.15 V
110 – 4.18 V
111 – Invalid Setting
(1) EOC Note: Maximum output current when VBAT < 3.0 V.
(2) V_TERM Note: Unique settings available for battery temperatures 0-10°C, 10-45°C, 45-50°C, and 50-60°C. For <0°C and
>60°C, charging is disabled and a fault is set.
Specifications subject to change
WWW.TRIUNESYSTEMS.COM
- 14 -