V-102-1A4 Datasheet, PDF (10/16 Pages) List of Unclassifed Manufacturers – Miniature Basic Switch
V
Miniature Basic Switch
Contact Specifications
Item
Model
Specification
Contact Material
Gap (standard value)
Inrush NC
current NO
Minimum applicable load
(reference value)
V-21
50 A
max.
V-16
V-15
Rivet
Silver alloy
1 mm
40 A
max.
30 A
max.
DC5V 160mA
V-10
Silver
24 A
max.
V Ratings
Model
V-21
V-16
V-15
V-10
Item
Rated voltage
AC250V
DC125V
DC250V
AC250V
DC125V
DC250V
AC250V
DC125V
DC250V
AC250V
DC125V
DC250V
Resistive load
21 A
0.6 A
0.3 A
16 A
0.6 A
0.3 A
15 A
0.6 A
0.3 A
10 A
0.6 A
0.3 A
Note. The above rating values apply under the following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5% RH
(3) Operating frequency: 30 operations/min
Approved Standards
UL (UL1054)/CSA (CSA C22.2 No.55)
Rated voltage
125 VAC
250 VAC
125 VDC
250 VDC
Model V-21
V-16
V-15
V-10
21A 1/2HP 16A 1/2HP 15A 1/2HP 10A 1/2HP
0.6A
0.3A
VDE (EN61058-1)
Consult your OMRON sales representative for specific models
with VDE approvals.
Rated voltage
AC250V
Model
V-21
20(4)A
V-16
16(4)A
Testing conditions: 5E4 (50,000 operations), for models of V-21:
T80 (0°C to 80°C), for models of V-16: T105 (0°C to 105°C)
Characteristics
Item
Model
Permissible operating speed
Permissible operating
frequency
Mechanical
Electrical
Insulation resistance
Contact resistance (initial value)
Between terminals of the
same polarity
Dielectric strength *1
Between current-carrying
metal parts and ground
Between each terminals and
non-current-carrying metal
parts
Vibration resistance *2 Malfunction
Durability
Shock resistance *2
Malfunction
Mechanical
Durability *3
Electrical
Degree of protection
Degree of protection against electric shock
Proof tracking index (PTI)
Ambient operating temperature
Ambient operating humidity
Weight
V-10
V-15
V-16
0.1mm to 1 m/s max. (pin plunger models)
600 operations/min max. (pin plunger models)
60 operations/min
100MΩ min. (at 500 VDC with insulation tester)
15mΩ max.
AC1,000V 50/60Hz 1min
V-21
AC1,500V 50/60Hz 1min AC1,500V 50/60Hz 1min
AC2,000V 50/60Hz 1min
AC1,500V 50/60Hz 1min AC1,500V 50/60Hz 1min
AC2,000V 50/60Hz 1min
10 to 55 Hz, 1.5-mm double amplitude
1,000 m/s2 {approx. 100 G} max.
200 m/s2
{approx. 20G} max.
300 m/s2 {approx. 30 G} max.
50,000,000 operations min. (60 operations/min)
300,000 operations min.
(30 operations/min)
Heat resistive: 50,000
operations min
(30 operations/min)
100,000 operations min.
(30 operations/min)
Heat resistive: 20,000
operations min
(30 operations/min)
100,000 operations min.
(30 operations/min)
IEC IP40
Class I
175
-25°C to +80°C (Heat resistive: -25°C to +150°C) (at ambient humidity of 60% max.)
(with no icing or condensation)
85% max. (for +5°C to +35°C)
Approx. 6.2g (pin plunger models)
Note. The data given above are initial values.
*1. The dielectric strength shown in the table indicates a value for models with a Separator.
*2. For the pin plunger models, the above values apply for use at the free position and total travel position. For the lever models, they apply at the total travel position.
Close or open circuit of the contact is shorter than 1 ms.
*3. For testing conditions, consult your OMRON sales representative.
10