English
Language : 

LP150X1 Datasheet, PDF (17/20 Pages) List of Unclassifed Manufacturers – DATA DISPLAY AG LP150X1 15.0 XGA TFT LCD PRELIMINARY SPECIFICATION
SPECIFICATIONS
TITLE: LP150X1 LIQUID CRYSTAL DISPLAY
LP150X1 REV. 1.0 PAGE 17 OF 20
15. HANDLING PRECAUTIONS
Please pay attention to the followings when you use this TFT-LCD module with
backlight unit.
15.1 Mounting Precaution
• LCD module must be mounted via mounting holes arranged in 4 corners. Be
sure to turn off the power when connecting or disconnecting the circuit.
• Note that the polarizers are easily damaged. Pay attention not to scratch or
press this surface with any hard object.
• When the LCD surface become dirty, please wipe it off with a soft material such
as cotton ball.
• Protect the module from the ESD as it may damage the electronic circuit (C-
MOS). Make certain that human body is grounded with wrist bend.
• Do not disassemble the module and be careful not to incur a mechanical shock
that might occur during installation. It may cause permanent damage.
• Do not leave the module in high temperatures, Particularly in areas of high
humidity for a long time.
• The module not be expose to the direct sunlight.
• Avoid contact with water as it may a short circuit within the module.
15.2 Operating Precaution
• The spike noise causes the faulty operation of circuits. Be lower the spike noise
as follows: VDD=±200mV, V1=±200mV( Over and under shoot voltage.)
• Response time depends on the temperature (in lower temperature, it becomes
longer).
• Brightness depends on the temperature (in lower temperature, it becomes
lower). And in lower temperature, response time for which brightness comes to
be stable after turn on becomes longer.
• Be careful for condensation at sudden temperature change. Condensation
makes damage to polarizer or electrical contact part. And after fading
condensation, smear or spot will occur.
• When fixed pattern are displayed at long times, remnant image is likely to occur.
• Module has high frequency circuit. If you need to shield the electromagnetic
noise, please do in yours.
• When backlight unit is operating, it sounds. If you need to shield the noise,
please do in yours.
15.3 Electrostatic Discharge Control
Since module is composed with electronic circuit, it is not strong to electrostatic
discharge. Make certain that treatment persons are connected to ground through list
band and so on. Furthermore, don’t touch I/F pin directly.
DATA DISPLAY AG
Industriestrasse 1
D-82110 Germering
APRIL 2001
http://www.datadisplay.de
Tel.: +49-89-894450-0
Fax: +49-89-894450-90