When attaching a heat sink to the G3NA, apply Silicone Grease or
equivalent heat conductive grease on the heat sink. (Toshiba Sili-
con, Shinetsu Silicon, etc.)
Tighten the mounting screws of the heat sink with a torque of 0.78 to
0.98 N S m.
EN55011 Measurement of Mains Terminal Disturbance
Voltage
The G3NA-UTU conforms to EN55011 standards when a capacitor
is connected to the load power supply as shown in the following cir-
cuit diagram.
Input
G3NA-UTU
Load
Output
G3NA
Recommended Capacitor:
Nissei Denki’s MKT-series R40 (1 µF)
The output terminal side of the G3NA-D210B is connected to a built-
in diode for protecting the SSR from damage that may result from
reverse connection. The SSR, however, cannot withstand one min-
ute or more if the wires are connected in reverse order. Therefore,
pay the utmost attention not to make polarity mistakes on the load
side.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K067-E1-1D