G3NA Datasheet, PDF (2/9 Pages) List of Unclassifed Manufacturers – Solid-state Relay
G3NA
G3NA
Accessories (Order Separately)
Heat Sink
The following heat sinks are thin and can be DIN-track mounted
(except Y92B-P250).
See Dimensions for details.
Model
Y92B-N50
Applicable SSR
G3NA-205B, G3NA-210B, G3NA-D210B,
G3NA-410B, G3NE-205T(L), G3NE-210T(L)
Y92B-N100
Y92B-N150
Y92B-P250
G3NA-220B, G3NA-420B, G3NE-220T(L)
G3NA-240B, G3NA-440B
G3NA-450B
Low-cost Models
Model
Y92B-A100
Y92B-A150N
Y92B-A250
Applicable SSR
G3NA-205B, G3NA-210B, G3NA-D210B,
G3NA-220B, G3NA-410B, G3NA-420B
G3NA-240B, G3NA-440B
G3NA-440B
Mounting Bracket
Used to mount the G3NA with a mounting dimension of 56 mm.
Model
Applicable SSR
R99-11
G3NA-240B, G3NA-440B
See Dimensions for details. (Refer to page 164.)
Specifications
Ratings
Input (Ambient Temperature: 25°C)
Model
Rated voltage
Operating voltage
Impedance
Voltage level
Must operate
voltage
Must release
voltage
G3NA-2jjB 5 to 24 VDC
4 to 32 VDC
7 mA max.*
4 VDC max.
1 VDC min.
100 to 120 VAC
75 to 132 VAC
36 kΩ±20%
75 VAC max.**
20 VAC min.**
200 to 240 VAC
150 to 264 VAC
72 kΩ±20%
150 VAC max.**
40 VAC min.**
G3NA-4jjB 5 to 24 VDC
4 to 32 VDC
5 mA max.*
4 VDC max.
1 VDC min.
G3NA-D210B 100 to 240 VAC
75 to 264 VAC
72 kΩ±20%
75 VAC max.
20 VAC min.
Note:
The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to
120 VAC, the input impedance is measured at 120 VAC).
*With constant current input circuit system. The impedance for the G3NA-jjjB-UTU is 15 mA max.
**Refer to the Engineering Data for further details.
Output
Model
G3NA-205B
G3NA-210B
G3NA-410B
G3NA-220B
G3NA-420B
G3NA-240B
G3NA-440B
G3NA-450B
G3NA-D210B
Rated load voltage
24 to 240 VAC
200 to 480 VAC
24 to 240 VAC
200 to 480 VAC
24 to 240 VAC
200 to 480 VAC
200 to 480 VAC
5 to 200 VDC
Load voltage range
19 to 264 VAC
180 to 528 VAC
19 to 264 VAC
180 to 528 VAC
19 to 264 VAC
180 to 528 VAC
180 to 528 VAC
4 to 220 VDC
Applicable load
Load current
With heat sink*
Without heat sink
0.1 to 5 A
0.1 to 3 A
0.1 to 10 A
0.1 to 4 A
0.2 to 10 A
0.2 to 4 A
0.1 to 20 A
0.1 to 4 A
0.2 to 20 A
0.2 to 4 A
0.1 to 40 A
0.1 to 6 A
0.2 to 40 A
0.2 to 6 A
0.2 to 50 A
0.2 to 6 A
0.1 to 10 A
0.1 to 4 A
Inrush current
60 A (60 Hz, 1 cycle)
150 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
20 A (10 ms)
*When OMRON’s heat sink (refer to the accessories) or a heat sink of specified size is used.
158