English
Language : 

D4DS Datasheet, PDF (3/12 Pages) List of Unclassifed Manufacturers – Safety-Door Switch
D4DS
Specifications
886-3-5753170
86-755-83289224
Http://www.100y.com.tw
J APPROVED STANDARD RATINGS
TÜV (EN60947-5-1)
Utilization category
Rated operating current (Ie)
Rated operating voltage (Ue)
AC-15
2A
400 V
Note: Use a 10-A fuse type gl or gG as a short-circuit protection device that conforms to IEC269.
UL (UL508/CSA C22.2 No.14)
A600
Rated voltage
120 VAC
240 VAC
480 VAC
600 VAC
Carry current
10 A
Current
Make
60 A
30 A
15 A
12 A
Break
6A
3A
1.5 A
1.2 A
Volt-amperes
Make
7,200 VA
Break
720 VA
J CHARACTERISTICS
Degree of protection (see note 1)
Life expectancy (see note 2)
Operating speed
Contact gap
Operating frequency
Positive opening force (see note 3)
Positive opening travel (see note 3)
Insulation resistance
Contact resistance
Dielectric strength
Rated insulation voltage (Ui)
Conditional short-circuit current
Short-circuit protective device (SCPD)
Switching overvoltage
Pollution degree (operating environment)
Conventional enclosed thermal current
(Ithe)
Protection against electric shock
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
IP65 (EN60947-5-1)
Mechanical: 1,000,000 operations min.
Electrical: 150,000 operations min.
0.1 m/s to 0.5 m/s
2 x 2.0 mm min.
30 operations/minute min.
58.84 N min.
10 mm min.
100 MΩ min. (at 500 VDC) between terminals of same polarity, between terminals of
different polarity, between each terminal and ground, and between each terminal and
non-current-carrying metal part
25 mΩ max. (initial value)
Uimp 4 kV between terminals of same polarity, between terminals of different polarity, and
between each terminal and non-current-carrying metal part (EN60947-5-1)
400 V (EN60947-5-1)
100 A (EN60947-5-1)
10 A, fuse type gI or gG (IEC269)
1,500 V max. (EN60947-5-1)
3 (EN60947-5-1)
10 A (EN60947-5-1)
Class II (double insulation)
Malfunction: 10 to 500 Hz, 0.65-mm single amplitude with an imposed acceleration of
100 m/s2 max.
Destruction: 1,000 m/s2 min.
Malfunction: 300 m/s2 min.
Operating: --30°C to 70°C (with no icing)
Operating: 95% max.
Approx. 76 g (for D4DS-15FS)
Note: 1.
2.
3.
Although the Switch casing resists dust, oil, and water, make sure that the keyhole on the head is free from dust, oil, water, and
chemical, or the D4DS may wear out, break, or malfunction.
Life expectancy values are calculated at an operating temperature of 5°C to 35°C, and an operating humidity of 40% to 70%.
Contact your OMRON sales representative for more detailed information on other operating environments.
These figures are minimum requirements for safe operation.
4