Frequency
Range
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
Resolution
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Accuracy [1]
0.1 % + 1
Input characteristics
Function
Overload
Protection
1100 V rms
1100 V rms
Input Impedance
(nominal)
> 10 MΩ < 100 pF
> 10 MΩ < 100 pF
Common Mode Rejection Ratio (1 kΩ unbalance)
> 120 dB at dc, 50 Hz or 60 Hz
> 60 dB, dc to 60 Hz
Normal Mode Rejection
> 60 dB at 50 Hz or 60 Hz
1100 V rms > 10 MΩ < 100 pF
Open circuit test voltage
1100 V rms
1100 V rms
< 2.7 V dc
< 2.7 V dc
> 120 dB at dc, 50 Hz or 60 Hz
Full scale voltage
To 6 MΩ
50 MΩ
< 0.7 V dc
< 0.9 V dc
2.000 V dc
> 60 dB at 50 Hz or 60 Hz
Typical short circuit current
< 350 mA
< 1.1 mA
Function
mA
Overload Protection
Fused, 44/100 A, 1000 V FAST Fuse
Overload
600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX recording
Function
DC functions
AC functions
Accuracy
The specified accuracy of the measurement function ± 12 counts for changes > 350 ms in duration.
The specified accuracy of the measurement function ± 40 counts for changes > 900 ms in duration.
General specifications
Maximum voltage between any
terminal and earth ground
Ω fuse protection from A inputs
Display (LCD)
Battery type
Battery life
RF communications
RF communication range
Temperature
Temperature coefficient
Relative humidity
Altitude
Electromagnetic compatibilty
EMI, RFI, EMC, RF
Safety compliance
Certifications
Ingress Protection (IP) rating
Size (H x W x L)
Weight
1000 V dc or ac rms
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Update rate: 4/sec
Votls, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Three AA Alkaline batteries, NEDA 15A IEC LR6
300 hours minimum
2.4 GHZ ISM Band
20 meters
Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C)
Operating: 2,000 m
Storage: 12,000 m
EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249,
FCCID : T68-FWCS IC:6627A-FWCS
US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
CSA, FCC, CE
IP54
4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
340 g (12 oz)
3 Fluke Corporation Fluke CNX 3000 Series Test Tools. The Fluke Wireless Team.