7. General Precautions
SPEC NO.: A043-13-TT-101
PAGE: 20/22
7.1. Safety
Liquid crystal is poisonous. Do not put it in your mouth. If liquid crystal touches your
skin or clothes, wash it off immediately by using soap and water.
7.2. Handling
1. The LCD panel is plate glass. Do not subject the panel to mechanical shock or to
excessive force on its surface.
2. The polarizer attached to the display is easily damaged. Please handle it carefully
to avoid scratch or other damages.
3. To avoid contamination on the display surface, do not touch the module surface
with bare hands.
4. Keep a space so that the LCD panels do not touch other components.
5. Put cover board such as acrylic board on the surface of LCD panel to protect panel
from damages.
6. Transparent electrodes may be disconnected if you use the LCD panel under
environmental conditions where the condensation of dew occurs.
7. Do not leave module in direct sunlight to avoid malfunction of the ICs.
7.3. Static Electricity
1. Be sure to ground module before turning on power or operating module.
2. Do not apply voltage which exceeds the absolute maximum rating value.
7.4. Storage
1. Store the module in a dark room where must keep at 25±10℃ and 65%RH or less.
2. Do not store the module in surroundings containing organic solvent or corrosive
gas.
3. Store the module in an anti-electrostatic container or bag.
7.5. Cleaning
1. Do not wipe the polarizer with dry cloth. It might cause scratch.
2. Only use a soft sloth with IPA to wipe the polarizer, other chemicals might
permanent damage to the polarizer.
The copyright belongs to InnoLux. Any unauthorized use is prohibited.