Note 3: Definition of Response time
The response time is defined as the LCD optical switching time interval between
“White” state and “Black” state. Rise time (TON) is the time between photo detector
output intensity changed from 90% to 10%. And fall time (TOFF) is the time between
photo detector output intensity changed from 10% to 90%.
White (TFT OFF)
Black (TFT ON)
White (TFT OFF)
100%
90%
10%
0%
TON
TOFF
Fig. 4-3 Definition of response time
Note 4: Definition of contrast ratio
Luminance measured when LCD on the " White" state
Contrast ratio (CR) =
Luminance measured when LCD on the "Black" state
Note 5: Definition of color chromaticity (CIE1931)
Color coordinates measured at center point of LCD.
Note 6: All input terminals LCD panel must be ground while measuring the center area of
the panel.