English
Language : 

AT043TN13 Datasheet, PDF (12/25 Pages) List of Unclassifed Manufacturers – LCD MODULE SPECIFICATION
INNOLUX
3.3. Timing Characteristics
SPEC NO.: A043-13-TT-101
PAGE: 9/22
3.3.1. Timing Conditions
(TA = 25℃, VDD = 2.3V~3.5V, GND = 0V)
Item
Symbol
Values
Min. Typ.
Unit
Max.
Remark
Clock cycle
1/tC
-
9.00 15 MHz
Hsync cycle
1/fH
-
17.14 -
KHz
Vsync cycle
1/fV
-
59.94 -
Hz
Horizontal signal
th
-
525 -
CLK Note 1
Horizontal display period
thd
-
480 -
CLK
Horizontal Front porch
thf
2
-
-
CLK Note 2
Horizontal Pulse width
thp
2
41
-
CLK Note 2
Horizontal Back porch
thb
2
-
-
CLK Note 2
Vertical cycle
tv
-
286 -
H
Vertical display period
tvd
-
272 -
H
Vertical Front porch
tvf
2
2
-
H
Vertical Pulse width
tvp
2
10
-
H
Vertical Back porch
tvb
2
2
-
H
DISP Setup Time
tdiss
10
-
-
ns
DISP Hold Time
tdish
10
-
-
ns
Clock Period
PW CLK 66.7 -
-
ns
Clock Pulse High Period
PWH 26.7 -
-
ns
Clock Pulse Low Period
PWL 26.7 -
-
ns
Hsync Setup Time
ths
10
-
-
ns
Hsync Hold Time
thh
10
-
-
ns
The copyright belongs to InnoLux. Any unauthorized use is prohibited.