Absolute Maximum Ratings (Note 1)
Parameter
Power Supply Voltage (Pin 12)
Hall Input Voltage Range (Pin 3, 4)
Speed Control Input Voltage Range (Pin 10)
Minimum Speed Set Input Voltage Range (Pin 6)
Reference Output Load Current (Pin 5)
Op Amp Input Voltage Range (Pin 7, 8)
Op Amp Output (Pin 9, Note 4)
Voltage Range
Source or Sink Current
Slope Select Input Voltage Range (Pin 14)
Current Limit Set Input Voltage Range (Pin 2)
Frequency Generator / Rotor Lock Output (Pin 15)
Voltage Range
Sink Current
Drive Outputs (Pin 1, 16, Note 4)
Voltage Range
Sink Current
Source Current
Thermal Characteristics
SOP-16 Exposed Pad Package
Thermal Resistance, Junction to Air
Thermal Resistance, Junction to Pad
QSOP-16 Package
Thermal Resistance, Junction to Air
Operating Junction Temperature Range
Storage Temperature Range
IR Reflow Peak Temperature
Lead Soldering Temperature (10 sec)
Electrostatic Discharge (Note 2)
Human Body Model
Machine Model
Symbol
VDD
VIR(Hall)
VIR(S)
VIR(MSS)
IO(Ref)
VIR(OA)
Rating
-0.3 to 18
-0.3 to VDD
-0.3 to VDD
-0.3 to VDD
Internally
Limited
-0.3 to VDD
Unit
V
V
V
V
mA
V
VOR(OA)
-0.3 to VDD
V
IO(OA)
30
mA
VIR(LS)
-0.3 to VREF
V
VIR(ILim)
-0.3 to VREF
V
VOR(FG/RL)
-0.3 to 18
V
ISink(FG/RL)
20
mA
VD(Ø1/Ø2)
ISink(Ø1/Ø2)
ISource(Ø1/Ø2)
-0.3V to 36
1.5
-1.5
V
A
A
°C/W
RØJA
92
RØJC
15
RØJA
136
TJ(max)
-40°C to 125
°C
Tstg
-60°C to 150
°C
Treflow
260
°C
Tlead
300
°C
ESD
V
2000
250
Notes:
1. Absolute maximum ratings are limits beyond which operation may cause permanent damage to the device.
These are stress ratings only. Functional operation at or above these limits is not implied.
2. Human Body Model: 100 pF capacitor discharged through a 1.5 kΩ resistor into each pin.
Machine Model: 200 pF capacitor discharged directly into each pin.
3. These specifications are guaranteed only for the test conditions listed.
4. Maximum package power dissipation limits must be observed.
© Andigilog, Inc. 2006
-2-
www.andigilog.com
August 2006 - 70A04018