PR01 Datasheet, PDF (13/13 Pages) Vishay Siliconix – Power Metal Film Resistors
Phoenix Passive Components
IEC
60115-1
CLAUSE
IEC
60068-2
TEST
METHOD
4.24
3(Ca)
TEST
Damp heat
(steady state)
4.25.1
-
Endurance
(at 70 °C)
4.29
45(Xa)
Component solvent
resistance
See 2nd amendment to
IEC 60115-1
Pulse Load
PROCEDURE
REQUIREMENTS
PR01 5%
PR01 1%
56 days; 40 °C; 90 to 95% R.H.
loaded with 0.01Pn
1000 h loaded with Pn or Vmax
1.5 h ON and 0.5 h OFF
Rins min 103 MΩ
∆R/Rmax
±3% + 0.05 Ω
∆R/Rmax
±1% + 0.05 Ω
∆R/Rmax
±5% + 0.05 Ω
∆R/Rmax
±1% + 0.05 Ω
Isopropyl alcohol followed by
brushing in accordance with
MIL STD 202
No visible damage
See figs. 9 and 10