English
Language : 

OCX160 Datasheet, PDF (11/44 Pages) List of Unclassifed Manufacturers – OCX160 Crosspoint Switch
OCX160 Crosspoint Switch—Preliminary Data Sheet
1.3 RapidConfigure Interface
RapidConfigure (RC) is a 25 signal parallel interface that is used to program the OCX160 device. The 25
pins are allocated as follows:
RCA[6:0] = RapidConfigure Address A. RCA are input pins.
RCB[6:0] = RapidConfigure Address B. RCB are input pins.
RCI[3:0] = RapidConfigure Instruction Bits
RCO[4:0] = RapidConfigure Readback. RCO are output pins.
RC_CLK# = RapidConfigure Clock (negative edge clock)
RC_EN# = RapidConfigure Cycle Enable (active low)
1.3.1 RapidConfigure Programming Instructions
The RC interface supports both write and read types of operations:
1. Write Operations (reset crosspoint and Input or Output Buffer (IOB), configure an
Output Buffer, connect/disconnect crosspoint)
2. Read Operations (Output Buffer and crosspoint configuration read).
Table 3 RapidConfigure Programming Instructions
RCI[3:0]
0000
0001
0010
RCA[6:0]
X
RCB[6:0]
X
0011
X
Input Port
Address
0100 Output Port
Data
Address
0101
Cycle 1 Output Port Intput Port
Address
Address
RCO[4:0]
X
Instruction
Description
Reserved
Reserved
Reset Crosspoint
Array
Reset the entire crosspoint array to no
connect. All Output Buffers remain
unchanged by this operation.
Set Array to Broadcast
mode
Connects the input selected by RCB[6:0]
to all output ports and disconnects all
other inputs. The Global Update
(UPDATE#) pin must be held high
during Broadcast mode. Activating the
Global Update pin returns the array to
the previous program condition.
Configure an Output Program an Output Buffer specified by
Buffer
RCA[6:0].
See Table 5 for RCB[6:0] bit assignment
and buffer functionality.
Readback Crosspoint, This is a two-cycle instruction.
Output Buffer status
Specify the crosspoint connect status at
input location specified by RCA[6:0] to
the output location specified by
RCB[6:0].
I-Cube, Inc.
[Rev. 1.6] 2/20/01
11