English
Language : 

E-1071 Datasheet, PDF (3/6 Pages) ETAL Group – Designed for inductive loads (DC 24 V)
Solid State Remote Power Controller E-1071-623/627
Operating modes
mode
fault-free
wire break load short
circuit (1)
control input
(terminals 6 and 7)
»0« »1« »0« »1« »0«
»1«
LED YELLOW – control c. 0
1
0
1
0
1
1
1
0
0
0
0
LED GREEN - O.K.
0
0
1
1
0
0
LED RED - wire break
0
0
0
0
1
1
LED RED - fault
status function
(terminal 9)
status operation
(terminal 8)
1
1
0
0
0
0
0
1
0
0
0
0
physical isolation
0
0
0
0
0
1
UB too low/
high (2)
faulty
setting
»0« »1«
0
1
0
0
0
0
1
1
0
0
0
0
0
0
Notes:
1 Short circuit: load (+) to load (-)
2 Underoltage: device disconnects at 28 V and reconnects at 29.4 V
Overvoltage: device disconnects at 60 V and reconnects at 57 V
1 - LED status output carries to plus potential
0 - LED status output is non-conductive
Dimensions
Schematic diagram
max. 60VDC/0.1A 10
+Ua
status
function
SF
9
sotpaeturastionSB 8
5
-Ua
max. 35 V DC
+US
6
control
input
7
-US
current rating
presetting
0
1
2
+
physical
isolation
off
control and
monitoring
electronics
1
+UB
(28...60 V DC)
3
+
solenoid
load
4
-
2
-UB
gb gn rt rt + -
LED-indication current-proportional
voltage output U(I)
129 OFF condition
5.08
124 ON condition
4.88
121
45
4.76
1.77
119.5
4.70
5
1646
rail EN 50022-35x7.5
(not included in delivery)
This is a metric design and millimeter dimensions take precedence ( mm )
inch
www.e-t-a.de
3