English
Language : 

EN25QH64 Datasheet, PDF (17/65 Pages) Eon Silicon Solution Inc. – 64 Megabit Serial Flash Memory with 4Kbyte Uniform Sector
Table 5. Manufacturer and Device Identification
OP Code
ABh
90h
9Fh
(M7-M0)
1Ch
1Ch
(ID15-ID0)
7017h
(ID7-ID0)
16h
16h
EN25QH64
Enable Quad Peripheral Interface mode (EQPI) (38h)
The Enable Quad Peripheral Interface mode (EQPI) instruction will enable the flash device for Quad
SPI bus operation. Upon completion of the instruction, all instructions thereafter will be 4-bit multiplexed
input/output until a power cycle or “ Reset Quad I/O instruction “ instruction, as shown in Figure 5. The
device did not support the Read Data Bytes (READ) (03h), Dual Output Fast Read (3Bh) and Dual
Input/Output FAST_READ (BBh) modes while the Enable Quad Peripheral Interface mode (EQPI) (38h)
turns on.
Figure 5. Enable Quad Peripheral Interface mode Sequence Diagram
Reset Quad I/O (RSTQIO) (FFh)
The Reset Quad I/O instruction resets the device to 1-bit Standard SPI operation. To execute a Reset
Quad I/O operation, the host drives CS# low, sends the Reset Quad I/O command cycle (FFh) then,
drives CS# high. This command can’t be used in Standard SPI mode.
This Data Sheet may be revised by subsequent versions
17
or modifications due to changes in technical specifications.
©2013 Eon Silicon Solution, Inc.,
Rev. J, Issue Date: 2013/12/27