English
Language : 

EN25LF10 Datasheet, PDF (10/30 Pages) Eon Silicon Solution Inc. – 1 Megabit Serial Flash Memory with 4Kbytes Uniform Sector
EN25LF10
Figure 6. Write Disable Instruction Sequence Diagram
Read Status Register (RDSR) (05h)
The Read Status Register (RDSR) instruction allows the Status Register to be read. The Status
Register may be read at any time, even while a Program, Erase or Write Status Register cycle is in
progress. When one of these cycles is in progress, it is recommended to check the Write In
Progress (WIP) bit before sending a new instruction to the device. It is also possible to read the
Status Register continuously, as shown in Figure 7.
Figure 7. Read Status Register Instruction Sequence Diagram
Table 6. Status Register Bit Locations
S7
S6
SRP
0
S5
S4
S3
S2
S1
S0
0
BP2
BP1
BP0
WEL
WIP
Status Register Protect
Reserved Bits
Block Protect Bits
Write Enable Latch
Write In Progress
Note : In OTP mode, SRP bit is served as OTP_LOCK bit.
This Data Sheet may be revised by subsequent versions 10 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw