English
Language : 

HPS3000 Datasheet, PDF (7/7 Pages) Emerson Network Power – 3000 W output power
Embedded Power for
Business-Critical Continuity
LED INDICATORS
There will be a green POWER LED (PWR) to indicate that AC is applied to the
PSU and standby voltage is available when blinking.This same LED should go
solid when the 48 V output is enabled and operational.
Rev. 7.10.09_81
HPS3000 Series
Americas
 of 7
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
There will be an Amber Power Supply Fail LED (FAIL) to indicate that the power
supply has failed and a replacement of the unit is necessary.Faults including
UVP, OVP, OTP, or Fan Fail when PSON# is asserted “Logic Low” shall cause the
amber LED to turn on.The LED can be turned off by recycling PSON# signal or
by an AC power interruption more than 1 second.The LED shall be off when
PSON# is not asserted “Logic Low”.Refer to table 13 for conditions of the
LED’s:
Table 13
LED Indicators
Power Supply Condition
Power LED
(GREEN)
No AC power to PSU
OFF
AC present / Standby Output On
Blinking
Power supply 48 V output ON and OK
ON
Power supply failure (includes
OFF
overvoltage, overtemperature)
Fail LED
(AMBER)
OFF
OFF
OFF
ON
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.PowerConversion.com
techsupport.embeddedpower@
emerson.com
Current limit
ON
Blinking
MTBF
The power supply has a minimum MTBF of 300K hours using the Bell core 332,
issue 6 specification @ 25 °C and 40 °C, ambient, at full load.With the power
supply installed in a system in a 25 °C ambient environment and
operating at full load, capacitor life shall be 10 years, minimum for ALL
electrolytic capacitors contained within this power supply. The power supply
shall demonstrate a MTBF level of > 500,000 hours.
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
AC Power
Quality Assurance
Full QAV testing shall be conducted in accordance with Emerson Network
Power Standards with reports available upon request.
Connectivity
DC Power
Embedded Computing
Warranty
Emerson Network Power shall warrant the power supply to be free of defects
in materials and workmanship for a minimum period of one year from the date
of shipment, when operated within specifications.The warranty shall be fully
transferable to the end owner of the equipment powered by the supply.
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Ordering Information
Racks & Integrated Cabinets
Services
Model Number
HPS3000-9
Main Output
48 Vdc
Main Output
Current
62.0 A
Standby Output
5.0 V
Standby Current
3.0 A
Surge Protection
EmersonNetworkPower.com
Emerson Network Power and the Emerson
Network Power logo are trademarks and ser-
vice marks of Emerson Electric Co.
©2009 Emerson Electric Co.