English
Language : 

HPR12K-00 Datasheet, PDF (5/6 Pages) Emerson Network Power – Connecting the input power cable, output load cable and communication wire according to the below figure.
Embedded Power for
Business-Critical Continuity
Rev.06.09.10
HPR12K-00
5 of 6
5.4 Signal Output Connector CN3
Table 8 Signal Output Connector
Self Connector
Molex: 52986-2679
(Astec P/N: 13870011610)
Mating Connector
Tyco: 2-5175677-4
Figure 5: Connector CN3
Signal
SYS_GND
Table 7 Output Connection Definitions foe 5V Standby
Name Description
Pin Qty.
Standby GND
2
Pin Number (s)
1, 14
UNIT1_PRESENT#
Power supply present for Unit 1
1
2
UNIT2_PRESENT#
Power supply present for Unit 2
1
3
UNIT3_PRESENT#
Power supply present for Unit 3
1
4
UNIT4_PRESENT#
Power supply present for Unit 4
1
5
UNIT1_DCOK/PWOK#
Power OK output for Unit 1
1
6
UNIT2_DCOK/PWOK#
Power OK output for Unit 2
1
7
UNIT3_DCOK/PWOK#
Power OK output for Unit 3
1
8
UNIT4_DCOK/PWOK#
Power OK output for Unit 4
1
9
UNIT1_ACOK#
AC input present for Unit 1
1
10
UNIT2_ACOK#
AC input present for Unit 2
1
11
UNIT3_ACOK#
AC input present for Unit 3
1
12
UNIT4_ACOK#
AC input present for Unit 4
1
13
UNIT1_PSON#
Power enable input for Unit 1
1
15
UNIT2_PSON#
Power enable input for Unit 2
1
16
UNIT3_PSON#
Power enable input for Unit 3
1
17
UNIT4_PSON#
Power enable input for Unit 4
1
18
UNIT1_PSKILL
Minimize arching damage to the power pins
1
19
UNIT2_PSKILL
Minimize arching damage to the power pins
1
20
UNIT3_PSKILL
Minimize arching damage to the power pins
1
21
UNIT4_PSKILL
Minimize arching damage to the power pins
1
22
UNIT1_#ALERT
Warning signal
1
23
UNIT2_#ALERT
Warning signal
1
24
UNIT3_#ALERT
Warning signal
1
25
UNIT4_#ALERT
Warning signal
1
26