English
Language : 

DRC-24V100W1AX Datasheet, PDF (1/11 Pages) Delta Electronics, Inc. – Protection Class II, Double Isolation
TECHNICAL DATASHEET
Chrome DIN Rail Power Supply
24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1A□
Highlights & Features
– Protection Class II, Double Isolation
(No Earth connection is required)
– Universal AC input voltage and full power up to 55°C
– Power will not de-rate for the entire input voltage range
– Up to 89.0% efficiency @ 230Vac
– NEC Class 2 / Limited Power Source (LPS) certified
– Overvoltage / Overcurrent / Over Temperature Protections
Safety Standards
CB Certified for worldwide use
*This picture is for reference to DRC-24V100W series only.
Model Number:
DRC-24V100W1A☐
Unit Weight:
0.35 kg (0.77 lb)
Dimensions (L x W x D): 91.0 x 89.9 x 55.6 mm
(3.58 x 3.54 x 2.19 inch)
General Description
The DRC-24V100W1A☐ is part of the Chrome DIN Rail Power Supply series, which is designed for use in compact cabinets for home
automations and the food and beverage industry. Delta’s Chrome DIN Rail Power Supply series offers double isolated input. This
means that no Earth connection is required thus resulting in low leakage current. This product provides a universal input voltage range
of 90-264Vac, and a wide temperature range of -25°C to 71°C. The Chrome series is certified to safety standard according to
IEC/EN/UL 60950-1 Information Technology Equipment (ITE) and UL 508 Industrial Control Equipment (ICE). The series is also fully
compliant with RoHS Directive 2011/65/EU for environmental protection. NEC Class 2 and Limited Power Source (LPS) approvals are
available for this product.
Model Information
Chrome DIN Rail Power Supply
Model Number
DRC-24V100W1A☐
Input Voltage Range
90-264Vac (125-375Vdc)
Rated Output Voltage
24Vdc
Rated Output Current
3.80A
Model Numbering
DR
DIN Rail
C–
24V
Product Series
Output Voltage
C - Isolation Class II
Power Supply
100W
Output Power
(100W series)
1
Single Phase
A
No PFC
□
Z – Black Plastic Case
G – Grey Plastic
1
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.