ES238 Datasheet, PDF (24/37 Pages) Cyrustek corporation – 6000 Counts DMM / Peak | |||
|
◁ |
ES238
6000 Counts DMM / Peak
3.5. Max/Min + HOLD
The meter displays the maximum or minimum value of the input in Max/Min mode. When MMX
key is pressed for the first time, the meter displays the maximum value. The meter displays the
minimum value, when it is pressed again. When MMX key is pressed for the third time, the meter
displays current value. The meter returns to normal operation if MMX is pressed and held for longer
than one second. Pressing HOLD in Max/Min mode makes the meter stop updating the maximum or
the minimum value.
1 push<1s
Original state
(Automatic/manual) 1 push>1 sec
1 push>1s
1 push>1 sec
âMAXâ active 1push<1s âMINâ active 1push<1s âMaxâ âMINâ blink
max value
min value
current value
1push<1s
Push HOLD
Push HOLD
Push HOLD
âMAXâ âHâ active
âMINâ âHâ active
âMAXââMINâ âHâ blink
hold max value. 1push<1s hold min value. 1push<1s hold current value.
1push<1s
3.6. Relative + Max/Min + HOLD
Max/Min mode can be nested in REL mode. The meter displays the maximum or minimum value
relative to the reference when MMX is pressed in REL mode. Pressing HOLD under REL +
Max/Min makes the meter stop updating the LCD panel.
Original State
(Auto/Manual)
Push REL
Push REL
ãRELãactive.
The relative value
Push MMX
Push MMX > 1s
ãRELãandãMaxãactive. ãRELãandãMinãactive. ãRELããMaxããMinãblink.
Maximum rel. value
Minimum rel. value
Current rel. value
Push MMX
Push MMX
Push HOLD
Push HOLD
Push HOLD
ãRELã,ãMaxã,
ãRELã, ãMinã,
ãRELãã, Maxãã, Minã,
ãHãactive. Hold
ãHãactive. Hold
ãHãblink. Hold the
Push MMX
max. rel. value
min. rel. value
Push MMX
current rel. value
V 2.2
Push MMX
24
2015/12/15
|
▷ |