English
Language : 

ES238 Datasheet, PDF (20/37 Pages) Cyrustek corporation – 6000 Counts DMM / Peak
ES238
6000 Counts DMM / Peak
Measurement Mode Switching (Continued)
Measurement mode depends on the logic level of SLACDC, FC1, FC2, FC3, FC4, FC5 and KEY
selection. When FC5 is low, the KEY function is disabled in most modes. The measurement mode list
is shown below:
SLACDC FC1 FC2 FC3 FC4
Mode
KEY selection & Remaks
0
1
0
1
1
DC Voltage Measurement
----
0
1
1
0
1
23
Auto DC Current Measurement(µA)
----
0
1
1
1
1
23Auto DC Current Measurement(mA)
----
0
0
0
0
0
23
Auto DC Current Measurement(A)
----
0
1
1
1
0
0
1
1
0
0
Scan RSDC
3Manual DC 6.000A
Ω  Continuity  Diode  Cap  Scan
----
0
1
0
0
0
3Manual DC 60.00A
----
0
1
0
1
0
3Manual DC 600.0A
----
0
1
0
0
1
3Manual DC 6000A
----
0
0
0
1
1
Resistance Measurement
----
0
0
0
0
1
Continuity Check
----
0
0
1
1
1
Diode Measurement
----
0
0
0
1
0
Frequency Measurement
----
0
0
1
1
0
Capacitance Measurement
----
0
0
1
0
0
Auto Temperature Measurement
℃
0
0
1
0
1
DCmV
----
1
1
0
1
1
AC Voltage Measurement
1
1
1
0
1
23Auto AC Current Measurement(µA)
1
1
1
1
1
23
Auto AC Current Measurement(mA)
1
0
0
0
0
23
Auto AC Current Measurement(A)
LPF Full1K
LPF Full1K
LPF Full1K
LPF Full1K
1
1
1
1
0
EF mode
----
1
1
1
0
0
3Manual AC 6.000A
LPF Full1K
1
1
0
0
0
3Manual AC 60.00A
LPF Full1K
1
1
0
1
0
3Manual AC 600.0A
LPF Full1K
1
1
0
0
1
1
0
0
1
1
1
0
0
0
1
1
0
1
1
1
1
0
0
1
0
3Manual AC 6000A
1
ADP0 ( 6000 )
1ADP1 ( 600.0 )
1
ADP2 ( 60.00 )
1ADP3 ( 6.000 )
LPF Full1K
----
----
----
Set to LED mode if SEL2 is kept float
1
0
1
1
0
Capacitance Measurement (Clamp)
----
1
0
1
0
0
Auto Temperature Measurement
℉
1
0
1
0
1
ACmV
LPF Full1K
Note:
1. When FC5 is low, the ADP0, ADP1, ADP2 and ADP3 modes can’t display minus sign.
2. These modes could be designed for multi-meter current modes, please refer to section 1.4.
3. These modes could be designed for clamp-meter current modes, please refer to section 1.5.
V 2.2
20
2015/12/15