ES238 Datasheet, PDF (1/37 Pages) Cyrustek corporation – 6000 Counts DMM / Peak | |||
|
ES238
6000 Counts DMM / Peak
Features
ï¬ 6,000 counts LCD display with 31 analog bar-graph
ï¬ LQFP 128L package
ï¬ 3V DC power supply
ï¬ Slow ADC Conversion rate : 3 times/s
ï¬ Bar-graph ADC conversion rate : 30 times/s
ï¬ Full automatic measurement
ï¼ Voltage measurement : 600.0mV, 6.000V â 1000V
ï¼ Current measurement : μA/mA/A
ï¼ Frequency with Voltage or Current :
ï¼ Resistance measurement :
60.00Ω â 60.00MΩ
ï¼ Capacitance measurement :
6.000nF â 60.00mF
( Taiwan patent no.: 323347, 453443 )
ï¼ Capacitance measurement for Clampmeter mode :
6.000nF â 60.00mF
ï¼ Smart auto check for R / S / D / C mode
Resistance : 0.0Ω â 6.000MΩ
(Buz. On when R < 30Ω)
Capacitance : 0.500nF â 600.0uF
(Taiwan patent no.: 326361)
ï¼ Not contact AC electric field detection
ï¼ Frequency counter :
600.0Hz â 60.00MHz
ï¼ Duty cycle measurement :
5% â 95% (< 10kHz)
ï¬ Diode measurement & continuity check
ï¬ Hazardous AC/DC voltage (HV) indication
ï¬ 4 ADP modes with external reference voltage and
independent âADPâ user-defined segment on LCD
ï¬ Temperature mode with internal scale translation
circuit from 0C to 0F
ï¬ K-type thermocouple reference table compensation
(-200~1350 oC)
ï¬ Push functions :
ï¼ Peak-hold function
ï¼ VAHz function
ï¼ MAX/MIN function
ï¼ Relative function
ï¼ Zero function: DCA clampmeter only
ï¼ Back Light function
ï¼ KEY function
ï¼ Data Hold and delayed-hold function
ï¼ Range change function
ï¼ Semi-auto calibration operation
(Taiwan patent no.: 367334)
ï¬ Low pass filter mode for ACA/ACV measurement
(Taiwan patent no.: 362409)
ï¬ Band-gap reference voltage output
ï¬ Voltage overflow selection ( DC / AC : 1010V, DC /
AC : 610V)
ï¬ Serial data output ( RS232 format )
ï¬ LCD segment check when power on
ï¬ Auto power off ( 30min / 15min )
ï¬ Sleep state indicative signal output
ï¬ Re-power on
ï¬ On-chip buzzer driver
ï¬ Low battery detection
ï® Description
ES238 is an integrated analog-to-digital converter
with 6,000-count LCD with bar-graph display,
automatic range selection, and 3V DC power
supply. Automatic range selection is provided for
ACV/DCV measurement, resistance measurement,
current measurement, capacitance measurement,
and frequency counter. Expensive and bulky
mechanical range switches are not required. Other
features include peak-hold function, relative value
display, offset removing feature for DCA clamp
mode, data holding, maximum and minimum
value holding, duty cycle measurement, diode
measurement, peak-hold function, temperature
measurement, continuity checking, low battery
detection, auto power off, re-power on, backlight
driver, buzzer driver and RS232 data output.
V 2.2
1
2015/12/15
|
▷ |