Measurement mode depends on the logic level of SLACDC, FC1, FC2, FC3, FC4, FC5 and KEY
selection. When FC5 is low (pulled to V-), the KEY function is disabled in most modes. The
measurement mode list is shown below: (Note: FC6 is high)
SLACDC FC1 FC2 FC3 FC4
Mode
KEY selection & Remaks
0
1011
DC 200.0V
----
0
1101
DC 20.00V
----
0
1111
DC 200.0mV
----
0
1110
DC 2.000V
----
0
0000
DC 20.00A2
----
0
1100
20.00 Mâ¦
----
0
1000
DC 200.0mA23
----
0
1010
2.000 Mâ¦
----
0
1001
200.0 kâ¦
----
0
0011
200.0 â¦
----
0
0001
DC 2000 uA23
----
0
0111
DC 1000V
----
0
0 0 1 0 Frequency mode (AUTO)
----
0
0110
2.000 kâ¦
----
0
0100
1350 â
----
0
0101
20.00 kâ¦
----
1
1011
AC 200.0V
----
1
1101
AC 20.00V
----
1
1111
AC 200.0mV
----
1
1110
AC 2.000V
----
1
0000
AC 20.00A2
----
1
1100
Continuity mode
----
1
1000
AC 200.0mA23
----
1
1010
Diode mode
----
1
1001
ADP0 (2000)1
----
1
0011
ADP1 (200.0)1
----
1
0001
AC 2000uA23
----
1
0111
AC 1000V
----
1
0010
ADP2 (20.00)1
----
1
0110
EF mode
----
1
0100
2462 â
----
1
0101
ADP3 (2.000)1
----
Note:
1. When FC5 is low, the ADP0, ADP1, ADP2 and ADP3 modes canât display minus sign.
2. These modes could be designed for multi-meter current modes, please refer to section 1.2.
3. These modes could be designed for clamp-meter current modes, please refer to section 1.3.