English
Language : 

ES218 Datasheet, PDF (17/26 Pages) Cyrustek corporation – 2000 Counts Manual DMM
ES218
2000 Counts Manual DMM
Measurement mode depends on the logic level of SLACDC, FC1, FC2, FC3, FC4, FC5 and KEY
selection. When FC5 is low (pulled to V-), the KEY function is disabled in most modes. The
measurement mode list is shown below: (Note: FC6 is high)
SLACDC FC1 FC2 FC3 FC4
Mode
KEY selection & Remaks
0
1011
DC 200.0V
----
0
1101
DC 20.00V
----
0
1111
DC 200.0mV
----
0
1110
DC 2.000V
----
0
0000
DC 20.00A2
----
0
1100
20.00 MΩ
----
0
1000
DC 200.0mA23
----
0
1010
2.000 MΩ
----
0
1001
200.0 kΩ
----
0
0011
200.0 Ω
----
0
0001
DC 2000 uA23
----
0
0111
DC 1000V
----
0
0 0 1 0 Frequency mode (AUTO)
----
0
0110
2.000 kΩ
----
0
0100
1350 ℃
----
0
0101
20.00 kΩ
----
1
1011
AC 200.0V
----
1
1101
AC 20.00V
----
1
1111
AC 200.0mV
----
1
1110
AC 2.000V
----
1
0000
AC 20.00A2
----
1
1100
Continuity mode
----
1
1000
AC 200.0mA23
----
1
1010
Diode mode
----
1
1001
ADP0 (2000)1
----
1
0011
ADP1 (200.0)1
----
1
0001
AC 2000uA23
----
1
0111
AC 1000V
----
1
0010
ADP2 (20.00)1
----
1
0110
EF mode
----
1
0100
2462 ℉
----
1
0101
ADP3 (2.000)1
----
Note:
1. When FC5 is low, the ADP0, ADP1, ADP2 and ADP3 modes can’t display minus sign.
2. These modes could be designed for multi-meter current modes, please refer to section 1.2.
3. These modes could be designed for clamp-meter current modes, please refer to section 1.3.
Measurement Mode Switching (Continued)
V 1.5
17
2015/12/11