English
Language : 

CYP15G0201DXB Datasheet, PDF (30/46 Pages) Cypress Semiconductor – Dual-channel HOTLink II Transceiver
CYP15G0201DXB
CYV15G0201DXB
CYP(V)15G0201DXB DC Electrical Characteristics Over the Operating Range (continued)
Parameter
Description
Test Conditions
VOLC
Output LOW Voltage
(VCC referenced)
100Ω differential load
150Ω differential load
VODIF
Output Differential Voltage
|(OUT+) − (OUT−)|
100Ω differential load
150Ω differential load
Differential Serial Line Receiver Inputs: INA1±, INA2±, INB1±, INB2±
VDIFFS[21] Input Differential Voltage |(IN+) − (IN−)|
VIHE
Highest Input HIGH Voltage
VILE
Lowest Input LOW Voltage
IIHE
Input HIGH Current
VIN = VIHE Max.
IILE
Input LOW Current
VCOM[23, 24] Common Mode Input Range
VIN = VILE Min.
Min.
VCC – 1.4
VCC – 1.4
450
560
Max.
VCC – 0.7
VCC – 0.7
900
1000
Unit
V
V
mV
mV
100
1200
mV
VCC
V
VCC – 2.0
V
1350
µA
–700
µA
VCC–1.95 VCC – 0.05 V
Power Supply
ICC
Power Supply Current
REFCLK = Max.
Commercial
Industrial
ICC
Power Supply Current
REFCLK = 125 MHz
Commercial
Industrial
Typ.[23]
570
570
Max.[22]
700
710
700
710
Unit
mA
mA
mA
mA
AC Test Loads and Waveforms
3.3V
R1
R1 = 590Ω
R2 = 435Ω
CL ≤ 7 pF
CL
(Includes fixture and
R2
probe capacitance)
[27]
(a) LVTTL Output Test Load
3.0V
Vth = 1.4V
GND
2.0V
0.8V
2.0V
0.8V
Vth = 1.4V
≤ 1 ns
≤ 1 ns
[28]
(c) LVTTL Input Test Waveform
RL = 100Ω
RL
[27]
(b) CML Output Test Load
VIHE
VILE
20%
≤ 270 ps
80%
VIHE
80%
VILE
20%
≤ 270 ps
(d) CML/LVPECL Input Test Waveform
Notes:
23. The common mode range defines the allowable range of INPUT+ and INPUT− when INPUT+ = INPUT−. This marks the zero-crossing between the true and
complement inputs as the signal switches between a logic-1 and a logic-0.
24. Not applicable for AC-coupled interfaces. For AC-coupled interfaces, VDIFFS requirement still needs to be satisfied.
25. Maximum ICC is measured with VCC = MAX, RXCKSEL = LOW, with all TX and RX channels and Serial Line Drivers enabled, sending a continuous alternating
01 pattern to the associated receive channel, and outputs unloaded.
26. Typical ICC is measured under similar conditions except with VCC = 3.3V, TA = 25°C, RXCKSEL = LOW, with all TX and RX channels enabled and one Serial
Line Driver per transmit channel sending a continuous alternating 01 pattern to the associated receive channel. The redundant outputs on each channel are
powered down and the parallel outputs are unloaded.
27. Cypress uses constant current (ATE) load configurations and forcing functions. This figure is for reference only. 5-pF differential load reflects tester capacitance,
and is recommended at low data rates only.
28. The LVTTL switching threshold is 1.4V. All timing references are made relative to the point where the signal edges crosses this threshold voltage.
Document #: 38-02058 Rev. *G
Page 30 of 46