English
Language : 

CY8C34_13 Datasheet, PDF (101/130 Pages) Cypress Semiconductor – Programmable System-on-Chip (PSoC®)
PSoC® 3: CY8C34 Family Datasheet
11.6.6 USB
Table 11-50. USB DC Specifications
Parameter
Description
Conditions
Min Typ
VUSB_5
Device supply for USB operation
USB configured, USB regulator
4.35
–
enabled
VUSB_3.3
USB configured, USB regulator
3.15
–
bypassed
VUSB_3
USB configured, USB regulator
2.85
–
bypassed[54]
IUSB_Configured Device supply current in device active VDDD = 5 V, FCPU = 1.5 MHz
mode, bus clock and IMO = 24 MHz VDDD = 3.3 V, FCPU = 1.5 MHz
–
10
–
8
IUSB_Suspended Device supply current in device sleep VDDD = 5 V, connected to USB
–
0.5
mode
host, PICU configured to wake on
USB resume signal
VDDD = 5 V, disconnected from
USB host
–
0.3
VDDD = 3.3 V, connected to USB
–
0.5
host, PICU configured to wake on
USB resume signal
VDDD = 3.3 V, disconnected from
–
0.3
USB host
Max
5.25
3.6
3.6
–
–
–
–
–
–
Units
V
V
V
mA
mA
mA
mA
mA
mA
11.6.7 Universal Digital Blocks (UDBs)
PSoC Creator provides a library of pre-built and tested standard digital peripherals (UART, SPI, LIN, PRS, CRC, timer, counter, PWM,
AND, OR, and so on) that are mapped to the UDB array. See the component data sheets in PSoC Creator for full AC/DC specifications,
APIs, and example code.
Table 11-51. UDB AC Specifications
Parameter
Description
Conditions
Min Typ
Max
Datapath Performance
FMAX_TIMER Maximum frequency of 16-bit timer in a
UDB pair
–
–
50.01
FMAX_ADDER Maximum frequency of 16-bit adder in
a UDB pair
–
–
50.01
FMAX_CRC Maximum frequency of 16-bit
CRC/PRS in a UDB pair
–
–
50.01
PLD Performance
FMAX_PLD Maximum frequency of a two-pass PLD
function in a UDB pair
–
–
50.01
Clock to Output Performance
tCLK_OUT
Propagation delay for clock in to data 25 °C, VDDD ≥ 2.7 V
out, see Figure 11-61.
–
20
25
tCLK_OUT Propagation delay for clock in to data Worst-case placement, routing, and –
–
55
out, see Figure 11-61.
pin selection
Units
MHz
MHz
MHz
MHz
ns
ns
Note
54. Rise/fall time matching (TR) not guaranteed, see USB Driver AC Specifications on page 80.
Document Number: 001-53304 Rev. *Q
Page 101 of 130