English
Language : 

CPC7582_1 Datasheet, PDF (8/19 Pages) Clare, Inc. – Line Card Access Switch
CPC7582
1.6.4 Test Switches, SW5 and SW6
Parameter
Conditions
Symbol Minimum Typical Maximum
Unit
Off-state leakage current
+25° C
VSW (differential) = -320 V to GND
VSW (differential) = +260 V to -60 V
0.1
+85° C
VSW (differential) = -330 V to GND
VSW (differential) = +270 V to -60 V
ISW
-
0.3
1
μA
-40° C
VSW (differential) = -310 V to GND
VSW (differential) = +250 V to -60 V
0.1
RON
+25° C
+85° C
-40° C
ISW(ON) = ±10 mA, ±40 mA,
TBAT = -2 V
RON
-
38
-
46
70
Ω
28
-
DC current limit
+25° C
-
175
-
+85° C
VSW (on) = ±10 V
80
110
-
mA
-40° C
ISW
-
210
250
Dynamic current limit
(t ≤ 0.5 μs)
Test switches on, all other switches off,
apply ±1 kV at 10x1000 μs pulse, with
appropriate protection in place.
-
2.5
-
A
Logic input to switch output isolation
+25° C
VSW (TTEST, TLINE) = ±320 V,
0.1
logic inputs = gnd
+85° C
VSW (TTEST, TLINE) = ±330 V,
logic inputs = gnd
ISW
-
0.3
1
μA
-40° C
VSW (TTEST, TLINE) = ±310 V,
0.1
logic inputs = gnd
8
www.clare.com
R05