English
Language : 

CPC7582_1 Datasheet, PDF (10/19 Pages) Clare, Inc. – Line Card Access Switch
CPC7582
1.8 Protection Circuitry Electrical Specifications
Parameter
Conditions
Symbol
Minimum
Typical
Maximum Unit
Parameters Related to the Diodes in the Diode Bridge
Voltage drop at
continuous current
(50/60 Hz)
Apply ± dc current limit of break Forward
switches
Voltage
-
Voltage drop at surge Apply ± dynamic current limit of Forward
current
break switches
Voltage
-
Parameters Related to the Protection SCR
2.1
3
V
5
-
Surge current
-
-
-
-
*
A
Trigger current
Hold current
T=+25°C
T=+85°C
T=+25°C
T=+85°C
ITRIG
-
60 (CPC7582xA, xB)
70 (CPC7582xC)
-
-
35 (CPC7582xA, xB)
40 (CPC7582xC)
-
mA
-
100 (CPC7582xA, xB)
135 (CPC7582xC)
-
IHOLD 60 (CPC7582xA, xB) 70 (CPC7582xA, xB)
110 (CPC7582xC) 115 (CPC7582xC)
-
Gate trigger voltage IGATE = ITRIGGER**
VTBAT or
VRBAT
VBAT -4
-
VBAT -2
V
Reverse leakage current VBAT = -48 V
IVBAT
-
-
1.0
μA
On-state voltage
0.5 A, t = 0.5 μs
2.0 A, t = 0.5 μs
VTBAT or
VRBAT
-
VTBAT or
VRBAT
-
-3
-
V
-5
-
V
*Passes GR1089 and ITU-T K.20 with appropriate secondary protection in place.
**VBAT must be capable of sourcing ITRIGGER for the internal SCR to activate.
1.9 CPC7582xA/B Truth Table
State
INRINGING
INTEST
LATCH
TSD
Talk
0
0
Test
Ringing
All Off
0
1
0
1 or
1
0
Floating1
1
1
Latched
X
X
1
All off
X
X
X
02
1If TSD is tied high, thermal shutdown is disabled. If TSD is left floating, the thermal shutdown mechanism functions normally.
2Forcing TSD to ground overrides the logic input pins and forces an all off state.
Break
Switches
On
Off
Off
Off
Off
Ringing
Switches
Off
Off
On
Off
Unchanged
Off
Test
Switches
Off
On
Off
Off
Off
10
www.clare.com
R05