CPC7582
Table 9. Truth Table
Input
0V
5V
0V
5V
Don’t
Care
Access
TSD
Tip Break
Switch
0V
5V/Float5
On
0V
5V/Float5
Off
5V
5V/Float5
Off
5V
5V/Float5
Off
Don’t
0V6
Off
Care
Ring
Break
Switch
On
Off
Off
Off
Off
1 Idle/Talk State
2 Power Ringing State
3 Test out message waiting state.
4 All OFF State
5 If TSD = 5V, the thermal shutdown mechanism is disabled.
If TSD if floating, the thermal shutdown mechanism is active.
6 Forcing TSD to ground overrides the logic input pins and forces an all off state.
Ringing
Return
Switch
Off
On
Off
Off
Off
Ring
Switch
Off
On
Off
Off
Off
Tip
Access
Switch
Off
Off
On
Off
Off
Ring
Access
Switch
Off1
Off2
On3
Off4
Off4
Package Pinout
CPC7582
1
FGND
TBAT 2
TLINE 3 SW1
TRING 4
SW3
TACCESS 5
VDD
SW5
6
TSD 7
DGND 8
SCR
and
Trip
Circuit
16 VBAT
15 RBAT
SW2 14 RLINE
13 RRING
SW4
12
RACCESS
SW6
11
LATCH
10
INRING
9
INACCESS
* Only the CPC7582BA contains the protection SCR.
Pin
Name
Function
1
FGND
Fault ground
2
TBAT
Connect to TIP on SLIC side
3
TLINE
Connect to TIP on line side
4
TRING
Connect to return ground for ringing
generator
5
TACCESS
Test access
6
VDD
+5V supply
7
TSD
Temperature shutdown pin. Can be
used as a logic level input or output.
See Tables 6, 7 and 9 for more
details. As an output, will read +5V
when device is in its operational mode
and 0V in the thermal shutdown mode.
To disable the thermal shutdown
mechanism, tie this pin to +5V
(NOT Recommended).
8
DGND
Digital ground
9
INACCESS
Logic level switch control
10
INRING
Logic level input switch control
11
LATCH
Data latch control, active high,
transparent low
12
RACCESS
Test access
13
RRING
Connect to ringing generator
14
RLINE
Connect to RING on line side
15
RBAT
Connect to RING on SLIC side
16
VBAT
Battery voltage. Used as a reference
for protection circuit
Rev. 1.0
www.clare.com
7