English
Language : 

LCC120 Datasheet, PDF (3/7 Pages) Clare, Inc. – COMMON INPUT OptoMOS Relay
PERFORMANCE DATA*
LCC120
LCC120
Typical LED Forward Voltage Drop
(N=50 Ambient Temperature = 25°C, IF = 5mA)
35
30
25
20
15
10
5
0
1.17 1.19 1.21 1.23 1.25
LED Forward Voltage Drop (V)
LCC120 - FormA
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
35
30
25
20
15
10
5
0
330 340 350 360 370 380 390
Blocking Voltage (V)
LCC120 - FormB
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
30
25
20
15
10
5
0
1.2 2.0 2.8 3.6 4.4 5.2 6.0
LED Current (mA)
LCC120 - FormA
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 10mADC)
25
20
15
10
5
0
0.75 1.05 1.35 1.65 1.95 2.25
Turn-On (ms)
LCC120 - FormA
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC, IF=10mADC)
35
30
25
20
15
10
5
0
8.5 8.8 9.1 9.4 9.7 10.0 10.3
On-Resistance (Ω)
LCC120 - FormB
Typical Blocking Voltage Distribution
(N=50 Ambient Temperature = 25°C)
30
25
20
15
10
5
0
263 280 297 314 331 348 365
Blocking Voltage (V)
LCC120 - FormA
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
25
20
15
10
5
0
1.05 1.75 2.45 3.15 3.85 4.55 5.25
LED Current (mA)
LCC120 - FormB
Typical Turn-On Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 10mADC)
30
25
20
15
10
5
0
0.25 0.35 0.45 0.55 0.65 0.75
Turn-On (ms)
LCC120 - FormB
Typical On-Resistance Distribution
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC, IF=10mADC)
30
25
20
15
10
5
0
9.3 10.2 11.1 12.0 12.9 13.8 14.7
On-Resistance (Ω)
LCC120 - FormA
Typical IF for Switch Operation
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
25
20
15
10
5
0
1.05 1.75 2.45 3.15 3.85 4.55 5.25
LED Current (mA)
LCC120 - FormB
Typical IF for Switch Dropout
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC)
25
20
15
10
5
0
1.05 1.75 2.45 3.15 3.85 4.55 5.25
LED Current (mA)
LCC120 - FormA
Typical Turn-Off Time
(N=50 Ambient Temperature = 25°C)
(Load Current = 170mADC; IF = 10mADC)
25
20
15
10
5
0
0.23 0.32 0.41 0.50 0.59 0.68
Turn-Off (ms)
The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact
our application department.
Rev. 7
www.clare.com
3