LCC120 Datasheet, PDF (1/7 Pages) Clare, Inc. – COMMON INPUT OptoMOS Relay | |||
|
LCC120
COMMON INPUT OptoMOS® Relay
Load Voltage
Load Current
Max RON
LCC120
250
170
20
Units
V
mA
â¦
Description
LCC120 is a 250V, 170mA, 20⦠1-Form-C relay. It is ideal
for applications focused on peak load current handling
capabilities.
Features
⢠Small 8 Pin DIP Package
⢠Low Drive Power Requirements (TTL/CMOS
Compatible)
⢠No Moving Parts
⢠High Reliability
⢠Arc-Free With No Snubbing Circuits
⢠3750VRMS Input/Output Isolation
⢠FCC Compatible
⢠VDE Compatible
⢠No EMI/RFI Generation
⢠Machine Insertable, Wave Solderable
⢠Current Limiting, Surface Mount and Tape & Reel
Versions Available
Approvals
⢠UL Recognized: File Number E76270
⢠CSA Certified: File Number LR 43639-10
⢠BSI Certified:
⢠BS EN 60950:1992 (BS7002:1992)
Certificate #:7344
⢠BS EN 41003:1993
Certificate #:7344
Applications
⢠Telecommunications
⢠Telecom Switching
⢠Tip/Ring Circuits
⢠Modem Switching (Laptop, Notebook, Pocket Size)
⢠Hookswitch
⢠Dial Pulsing
⢠Ground Start
⢠Ringer Injection
⢠Instrumentation
⢠Multiplexers
⢠Data Acquisition
⢠Electronic Switching
⢠I/O Subsystems
⢠Meters (Watt-Hour, Water, Gas)
⢠Medical Equipment-Patient/Equipment Isolation
⢠Security
⢠Aerospace
⢠Industrial Controls
Ordering Information
Part #
LCC120
LCC120S
Description
8 Pin DIP (50/Tube)
8 Pin Surface Mount (50/Tube)
Pin Configuration
LCC120 Pinout
AC/DC Configuration
1
Do Not Use
2
+ Control
3
â Control
4
Do Not Use
8
Normally Closed Pole
7
6
Normally Open Pole
5
Switching Characteristics of
Normally Open (Form A) Devices
CONTROL
10ms
Switching Characteristics of
Normally Closed (Form B) Devices
CONTROL
10ms
+90%
LOAD 10%+
10%+
TON TOFF
+90%
+10%
TOFF
+90%
TON
DS-LCC120-R7
www.clare.com
1
|
▷ |