English
Language : 

LCC120 Datasheet, PDF (2/7 Pages) Clare, Inc. – COMMON INPUT OptoMOS Relay
LCC120
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Input Power Dissipation
Input Control Current
Peak (10ms)
Reverse Input Voltage
Total Power Dissipation
Isolation Voltage
Input to Output
Operational Temperature
Storage Temperature
Soldering Temperature
DIP Package
Surface Mount Package
(10 Seconds Max.)
1 Derate Linearly 1.33 mw/˚C
2 Derate Linearly 6.67 mw/˚C
Min Typ Max Units
-
- 1501 mW
-
- 50 mA
-
-1 A
-
-5 V
-
- 8002 mW
3750
-40
-40
-
- VRMS
- +85 °C
- +125 °C
-
- +260 °C
-
- +220 °C
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for an extended period may degrade the device and effect
its reliability.
Electrical Characteristics
Parameter
Conditions
Symbol Min
Typ
Output Characteristics @ 25°C
Load Voltage (Peak)
Load Current* (Continuous)
AC/DC Configuration
Peak Load Current
On-Resistance
AC/DC Configuration
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Capacitance
Input to Output
-
VL
-
-
-
10ms
IL
-
-
IL
-
-
IL=170mA
RON
-
16
VL=250V
ILEAK
-
-
IF=10mA, VL=10V
TON
-
-
IF=10mA, VL=10V
TOFF
-
-
50V; f=1MHz
COUT
-
50
-
-
-
3
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Voltage
Reverse Input Current
CommonCharacteristics @ 25°C
IL=170mA
-
IF=10mA
-
VR=5V
IF
10
-
IF
0.4
0.7
VF
0.9
1.2
VR
-
-
IR
-
-
Input to Output Capacitance
-
CI/O
-
3
Input to Output Isolation
-
VI/O
3750
-
*NOTE: If both poles operate simultaneously load current must be derated so as not to exceed the package power dissipation value.
Max
Units
250
V
170
mA
400
mA
20
Ω
1
µA
5
ms
5
ms
-
pF
-
pF
50
mA
-
mA
1.4
V
5
V
10
µA
-
pF
-
VRMS
2
www.clare.com
Rev. 7