English
Language : 

HBS2KGB4SP011C Datasheet, PDF (4/6 Pages) ITT Industries – Single Pole Standard Precision Snap-acting Switches
HB Series
Single Pole Standard Precision Snap-acting Switches
MOUNTING STYLE
S Standard
NOTE: Mounting holes will accept pins or screws of .139 dia. (3,53) max. on
1.000 ± .002 (25,4 ± 0,05) centers.
ACTUATOR
NOTE: Torque mounting screws 3 inlbs max.
OPTION CODE
A0
NO.
POLES FIG. DIM. A
DIM. B
SP
1
.86
1.120 ± .060
(21,8) (28,45 ± 1,52)
DIM. C
.38 dia.
(9,7Ø)
DIM. D
1.03
(26,2)
D0
SP
3
.92
.844 ± .020
(23,4) (21,44 ± 0,51)
—
—
F0
SP
2
.09
1.120 ± .050 .38 dia. .74
(2,3) (28,45 ± 1,27) (9,7Ø) (18,8)
J
J0
SP
4
.86
(21,8)
.860±.030
(21,84±0,76)
.64 dia. 0.33
(16,3Ø) (8,40)
P0
SP
5
.92
.625 ± .010
(23,4) (15,88 ± 0,25)
—
—
R5
SP
6
.92
(23,4)
.62
(15,7)
.50 dia. 0.61
(12,7Ø) (15,5)
T0
SP
7
1.310 .720 ± .060 1.03 dia.
(33,27) (18,28 ± 1,52) (26,2Ø))
—
TS*
SP
7
1.47
.720 ± .060 1.03 dia.
(37,3) (18,28 ± 1,52) (26,2Ø)
—
Y0
SP
8
.05
.720 ± .030 .74 dia. 2.65
(1,3) (18,29 ± 0,76) (18,8Ø) (6,73)
D
A
FIG. 1
Lever Roller
B
* Actuators sealed against the entrance of airborne
contaminants and/or splashing liquids.
D
A
B? .040
B
PANEL MOUNTING
C
A
FIG. 5
Pin Plunger
C
B
A
FIG. 3
Stub Plunger
A
D
B
A
D
C
B
FIG. 2
Lever Roller
C
FIG. 4
Plunger
.50 DIA.
(12,70?)
D
C
A
FIG. 6
Perpendicular Roller Plunger
C
A
B
B
FIG. 8
Reverse Acting Lever
J–52
FIG. 7
Lever
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
www.ck-components.com