English
Language : 

HBS2KGB4SP011C Datasheet, PDF (3/6 Pages) ITT Industries – Single Pole Standard Precision Snap-acting Switches
OPTION
CODE
KG
GF
KA
KC
KH
PB
HB Series
Single Pole Standard Precision Snap-acting Switches
OPERATING FORCE
MAXIMUM OPERATING
FORCE (OZ./GRAMS)
18
510
4
115
9
255
13
370
20
570
26
740
STANDARD CONTACT
SEPARATION (inch)
.020
.010
.010
.020
.040
.070
CONTACT
SEPARATION
.010
.020
.040
.070
OPERATING FORCE SPECIFICATION LIMITS
FOR VARIOUS CONTACT SEPARATIONS
OUNCES
4
79
13 14
18 20
26
30
STANDARD RANGE
MAXIMUM LIMITS AVAILABLE
NOTE: All listed differential travel characteristics are based on standard operating force
andcontact separation. For any other force or contact separation, consult Customer
Service Center.
Operating force varies with actuator option, see ACTUATOR option section.
ELECTRICAL RATING
OPTION CODE
MOVABLE CONTACT
STATIONARY CONTACT
ELECTRICAL RATING
B4
Fine silver.
Fine silver welded to
copper base.
20 AMPS @ 125, 250 & 480 V AC; 0.25 AMPS @ 250 V DC; 0.5 AMPS @
125 V DC (UL/CSA).
J
A2
5 AMPS @ 125 & 250 V AC (UL/CSA).
B6
Precious metal alloy.
Precious metal alloy.
20 AMPS @ 125, 250 & 480 V AC; 0.25 AMP @ 250 V DC; 0.5 AMP @
125 V DC; 3/4 HP @ 125 V AC; 1 1/2 HP @ 250 V AC (UL/CSA).
F5
Gold alloy.
Gold alloy.
Low level* to 1 AMP @ 125 V AC; 1 AMP @ 30 V DC (UL/CSA).
F9
Fine silver.
Fine silver welded to
copper base.
22 AMPS @ 125 & 277 V AC; 15 AMPS @ 480 V AC; 1/4 HP @ 125 V AC;
1/2 HP @ 250 V AC; 277 V AC (UL/CSA).
V3
Fine silver.
Fine silver welded to
copper base.
20 AMPS @ 125, 250, 480 V AC; 0.25 AMP @ 250 V DC, 0.5 AMP @
125 V DC (UL/CSA); 15 (10) AMPS @ 380 V~ T85 50E3 µ (VDE).
* Note: See Technical Data section of this catalog for RoHS compliant and compatible definition and specifications.
µ
~
T_ _
50E3
10(3)
EUROPEAN SYMBOLS
Microgap construction
(less than 4 mm).
Alternating current.
Maximum rated use temperature.
Cycles over 50,000 at rated current.
First number represents resistive
rating; second number represents
inductive (motor) rating.
All models
with all options,
also available.
Consult Customer Service center for availability and delivery of nonstandard ratings.
* Low Level=conditions where no arcing occurs during switching,
i.e., 0.4 VA max. @ 20 V AC or DC max.
AVAILABLE COMBINATIONS
OPERATING FORCE (oz.)
ELECTRICAL 4
9 13 18 20 26
RATING
GF KA KC KG KH PB
A2
•
•
•
•
•
•
B4
x
•
•
•
•
•
B6
x
x
x
•
•
•
F5
x
x
•
•
•
•
F9
x
x
x
•
•
•
X3
x
•
•
•
•
•
• AVAILABLE
x NOT AVAILABLE
J–51
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
www.ck-components.com