6.5 Interface Formats (address 04h)
7
DIF1
6
DIF0
5
ADC_OL1
4
ADC_OL0
3
DAC_OL1
2
DAC_OL0
CS42416
1
0
Reserved CODEC_RJ16
6.5.1 DIGITAL INTERFACE FORMAT (DIFX)
Default = 01
Function:
These bits select the digital interface format used for the ADC & DAC Serial Port when not in One-Line
Mode. The required relationship between the Left/Right clock, serial clock, and serial data is defined by
the Digital Interface Format and the options are detailed in Figures 11-13.
DIF1
0
0
1
1
DIF0
0
1
0
1
Description
Left-Justified, up to 24-bit data
I²S, up to 24-bit data
Right-Justified, 16-bit or 24-bit data
Reserved
Table 6. Digital Interface Formats
Format
0
1
2
-
Figure
13
12
11
-
6.5.2
ADC ONE_LINE MODE (ADC_OLX)
Default = 00
Function:
These bits select which mode the ADC will use. By default, One-Line Mode is disabled, but it can be
selected using these bits. Please see Figures 14 and 15 to see the format of One-Line Mode 1 and
One-Line Mode 2.
ADC_OL1
0
0
1
1
ADC_OL0
0
1
0
1
Description
DIF: take the DIF setting from reg04h[7:6]
One-Line #1
One-Line #2
Reserved
Table 7. ADC One-Line Mode
Format
-
3
4
-
Figure
-
14
15
-
6.5.3 DAC ONE_LINE MODE (DAC_OLX)
Default = 00
Function:
These bits select which mode the DAC will use. By default, One-Line Mode is disabled, but it can be
selected using these bits. Please see Figures 14 and 15 to see the format of One-Line Mode 1 and
One-Line Mode 2.
DAC_OL1
0
0
1
1
DAC_OL0
0
1
0
1
Description
DIF: take the DIF setting from reg04h[7:6]
One-Line #1
One-Line #2
Reserved
Table 8. DAC One-Line Mode
Format
-
3
4
-
Figure
-
14
15
-
DS602F1