English
Language : 

SA306 Datasheet, PDF (2/14 Pages) Cirrus Logic – 3 Phase Switching Amplifier
SA306
Product Innovation From
1. Characteristics and Specifications
NOTES:
1. (All Min/Max characteristics and specifications are guaranteed over the Specified Operating Condi-
tions. Typical performance characteristics and specifications are derived from measurements taken
at typical supply voltages and TC = 25°C).
Absolute Maximum Ratings
Parameter
Symbol
Min
Max
Units
SUPPLY VOLTAGE
VS
SUPPLY VOLTAGE
VDD
60
V
5.5
V
LOGIC INPUT VOLTAGE
OUTPUT CURRENT, peak, 10ms2 IOUT
POWER DISSIPATION, avg, 25ºC2 PD
TEMPERATURE, junction3
TJ
TEMPERATURE RANGE, storage TSTG
OPERATING TEMPERATURE, case TA
(-0.5)
−55
−40
(VDD+0.5)
V
17
A
100
W
150
°C
125
°C
125
°C
2. Long term operation at elevated temperature will result in reduced product life. De-rate internal power
dissipation to achieve high MTBF.
3. Output current rating may be limited by duty cycle, ambient temperature, and heat sinking. Under any
set of conditions, do not exceed the specified current rating or a junction temperature of 150°C.
Specifications
Parameter
Test Conditions2
SA306
Min Typ Max
SA306A
Min Typ Max
Units
LOGIC
INPUT LOW
1
*
V
INPUT HIGH
1.8
*
V
OUTPUT LOW
0.3
*
V
OUTPUT HIGH
3.7
*
V
OUTPUT CURRENT
(SC, Temp, ILIM/DIS1)
POWER SUPPLY
50
*
mA
VS
VS UNDERVOLTAGE
LOCKOUT, (UVLO)
UVLO 50
60
9
55
V
*
*
V
VDD
4.5
5.5
*
*
V
20 kHz (One phase
SUPPLY CURRENT, VS
switching at 50% duty
cycle) , VS=50V, VDD=5V
25
30
*
*
mA
20 kHz (One phase
SUPPLY CURRENT, VDD
switching at 50% duty
cycle) , VS=50V, VDD=5V
5
6
*
*
mA
* The specification of SA306A is identical to the specification for SA306 in applicable column to the left.