CS2100-OTP_09 Datasheet, PDF (15/26 Pages) Cirrus Logic – Fractional-N Clock Multiplier
5.4.2
CS2100-OTP
Ratio Modifier (R-Mod)
The Ratio Modifier is used to internally multiply/divide the currently addressed RUD (Ratio0-3 stored in the
register space remain unchanged). The available options for R-Mod are summarized in Table 2 on
page 15. R-Mod is enabled via the M2 pin in conjunction with the appropriate setting of the M2Config[2:0]
global parameter (see Section 5.7.2 on page 18).
RModSel[1:0]
00
01
10
11
R Modifier
0.5
0.25
0.125
0.0625
Table 2. Ratio Modifier
Referenced Control
Parameter Definition
Ratio 0-3................................“Ratio 0 - 3” on page 21
RModSel[1:0] ........................“R-Mod Selection (RModSel[1:0])” section on page 20
M2Config[2:0]........................“M2 Pin Configuration (M2Config[2:0])” on page 22
5.4.3
Effective Ratio (REFF)
The Effective Ratio (REFF) is an internal calculation comprised of RUD and the appropriate modifiers, as
previously described. REFF is calculated as follows:
REFF = RUD • R-Mod
To simplify operation the device handles some of the ratio calculation functions automatically (such as
when the internal timing reference clock divider is set). For this reason, the Effective Ratio does not need
to be altered to account for internal dividers.
Ratio modifiers which would produce an overflow or truncation of REFF should not be used. In all cases,
the maximum and minimum allowable values for REFF are dictated by the frequency limits for both the
input and output clocks as shown in the “AC Electrical Characteristics” on page 7.
Selection of the user defined ratio from the four stored ratios is made by using the M[1:0] pins.
Referenced Control
Parameter Definition
M[1:0] pins.............................“M1 and M0 Mode Pin Functionality” on page 17
5.4.4
Ratio Configuration Summary
The RUD is the user defined ratio for which up to four different values (Ratio0-3) can be stored in the one
time programmable memory. The M[1:0] pins then select the user defined ratio to be used as well as the
modal configuration set. The resolution/format for the RUD is selectable. R-Mod is applied accordingly.
The user defined ratio, ratio modifier, and automatic ratio modifier make up the effective ratio REFF, the
DS841F1
15