English
Language : 

CDB5461 Datasheet, PDF (11/27 Pages) Cirrus Logic – Evaluation Board and Software
CDB5461
is on means that the corresponding bit in the
Status Register is set (except the Invalid Com-
mand bit, which is inverted). The value present
in the Mask register may be changed by the
software during certain operations to provide
correct functionality of the CDB5461 board.
2.4.5 Cycle Count / PulseRateE /
PulseRateF / PulseWidth / VSAGlevel /
VSAGduration / Time Base Registers
These boxes display the values corresponding
register in both hexadecimal and decimal for-
mat. Each register can be modified by typing a
value in the corresponding Value: or HEX:
box.
2.4.6 Control Register
The Control Register contains various bits
used to activate or terminate various features
of the CS5461. Refer to the CS5461 data
sheet for description of the bits. The user is
able to turn each bit on or off individually. The
value of the Control Register is displayed in
HEX. Most of the Control Register bits are re-
served or unused. Only the usable bits are
displayed in the Setup Window.
Figure 3. Calibration Window
2.5 Calibration Window
The Calibration Window is used to display and
write to the CS5461 offset and gain calibration
registers. The user is also able to initiate the
CS5461’s calibration sequences that are used
to set the calibration values. Both AC and DC
calibrations can be run for offset and gain, for
either the voltage channel or the current chan-
nel, or both simultaneously. The user should
refer to the CS5461 data sheet for more details
on calibration.
11