English
Language : 

SMCW6150 Datasheet, PDF (6/16 Pages) celduc-relais – Solid State Relays For Motor Control
S/MOT/SMCW6150/A/22/07/99
1W240020
Page 6/16
Solid State Relays
For Motor Control
celduc®
relais
POWER
CHARACTERISTICS
Concerned Terminals
Voltage Range
Consumption
Frequency Range
Turn-on Time
INTERNAL SUPPLY ELECTRICAL CHARACTERISTICS
LABELS
VALUES
(Given at 20°C ambient unless otherwise specified)
3L2 & 5L3
Ue
200->480VAC
Is
1mA typical
f
40-65Hz
tm
100ms
CHARACTERISTICS
Concerned Terminals
Max Power Of The Motor
@400VAC Star Wiring (Y)
Max Power Of The Motor
@230VAC Star Wiring (Y)
Max Power Of The Motor
@400VAC Delta Wiring (D)
Max Power Of The Motor
@230VAC Delta Wiring (D)
Nom. Operating Voltage
Operating Voltage Range
Max. Non-repetitive Peak Voltage
POWER SIDE CHARACTERISTICS
LABELS
VALUES
(Given at 40°C ambient unless otherwise specified)
1L1, 2T1, 3L2, 4T2, 5L3, 6T3
Pn
15kW
Pn
8.6kW
Pn
26kW
Pn
Uen
Ue
Uep
15kW
230VAC & 400VAC
200->480VAC
1200V
Integrated Overvoltage Protection
Yes
510V size 14 varistors
AC53a Nom. Current according to
EN60947-4-2 (Induction Motor)
Ie
(AC53a)
22.5A
AC53a Max. Permanent Current
(Induction Motor)
Ie
(AC53a)
Max. AC1 Permanent Current
(Resistive Loads)
Non-repetitive Peak Overload
Current (1 cycle of 10ms)
Fusing Limit Current For Choosing
The Protecting Fuses
Min. Load Current
Max. Leakage Current
Power Factor
Operating Mains Frequency Range
Off-state Dv/Dt
Integrated Transient Voltage
Protection
Max. Current Rising Time
Direct Voltage Drop
Resistive Part
Of The Direct Voltage Drop
Threshold Part
Of The Direct Voltage Drop
Max. Junction Temperature
Junction/Plate Thermal Resistance
Per Power Element
Plate/Heatsink Thermal Resistance
Vertically Mounted Heatsink
Thermal Resistance
Heatsink Thermal Time Constant
Ith
(AC1)
ITSM
I2t
Iemin
Ilk
Pf
F
dv/dt
di/dt
Ud
rt
Vto
Tjmax
Rthjc
Rthcs
Rthra
Tthra
30A
50A
(65A if the wire cross-section is doubled
for each power terminal)
2000A
20000A2s
100mA
7mA
0->1
40->65Hz
500V/µs
YES
RC network
50A/µs
1.4V
2mΩ
0.9V
125°C
0.25°K/W
0.05°K/W
0.3°K/W
15min
REMARKS
See internal
diagram fig. 1
page 2
REMARKS
Device wired
inside the delta
Device wired
inside the delta
See curves
fig. 16 & 17
page 7
Hard conditions
See curve
fig. 15 page 7
Normal
conditions
See curve
fig. 15 page 7
E.g. softstarting
lamps
See Curve
fig. 14 page 7
@10ms
@400VAC50Hz
@Ith
@125°C
@125°C
Total = 3 power
elements
@∆Tra=60°C
@∆Tra=60°C