English
Language : 

CAT5409 Datasheet, PDF (4/17 Pages) Catalyst Semiconductor – Quad Digitally Programmable Potentiometers (DPPTM) with 64 Taps and 2-wire Interface
CAT5409
D.C. OPERATING CHARACTERISTICS
Over recommended operating conditions unless otherwise stated.
Symbol
ICC
ISB
ILI
ILO
VIL
VIH
VOL1
Parameter
Test Conditions
Min
Power Supply Current
fSCL = 400kHz
Standby Current (VCC = 5.0V) VIN = GND or VCC; SDA Open
Input Leakage Current
VIN = GND to VCC
Output Leakage Current
VOUT = GND to VCC
Input Low Voltage
-1
Input High Voltage
VCC x 0.7
Output Low Voltage (VCC = 3.0V)
IOL = 3 mA
Typ Max Units
1
mA
1
µA
10
µA
10
µA
VCC x 0.3 V
VCC + 1.0 V
0.4
V
CAPACITANCE
TA = 25°C, f = 1.0 MHz, VCC = 5V
Symbol Test
Conditions Min Typ
Max Units
CI/O(1) Input/Output Capacitance (SDA)
VI/O = 0V
8
pF
CIN(1) Input Capacitance (A0, A1, A2, A3, SCL, WP)
VIN = 0V
6
pF
A.C. CHARACTERISTICS
Over recommended operating conditions unless otherwise stated.
Symbol Parameter
Min Typ
fSCL
Clock Frequency
TI(1)
Noise Suppression Time Constant at SCL, SDA Inputs
tAA
tBUF(1)
SLC Low to SDA Data Out and ACK Out
Time the bus must be free before a new transmission can start 1.2
tHD:STA Start Condition Hold Time
0.6
tLOW
Clock Low Period
1.2
tHIGH
Clock High Period
0.6
tSU:STA Start Condition SetupTime (for a Repeated Start Condition)
0.6
tHD:DAT Data in Hold Time
0
tSU:DAT Data in Setup Time
100
tR(1)
SDA and SCL Rise Time
tF(1)
SDA and SCL Fall Time
tSU:STO Stop Condition Setup Time
0.6
tDH
Data Out Hold Time
50
POWER UP TIMING (1)
Over recommended operating conditions unless otherwise stated.
Symbol Parameter
Min Typ
tPUR Power-up to Read Operation
tPUW Power-up to Write Operation
Note:
(1) This parameter is tested initially and after a design or process change that affects the parameter.
Max
400
50
0.9
0.3
300
Units
kHz
ns
µs
µs
µs
µs
µs
µs
ns
ns
µs
ns
µs
ns
Max
1
1
Units
ms
ms
Document No. 2010, Rev. I
4