M-Series Parallel Pole - Form & Fit Drawings | 7
PARALLEL POLE TERMINAL OPTIONS
PUSH-IN STUD
10-32 SCREW W/ BUS BAR
.912 [23.16]
.652 [16.56]
1.125 [28.58]
1.000 [25.4]
.393 [9.97]
.100 [2.54]
.750 [19.05]
.154 [3.91]
.838 [21.29]
1.000 [25.4]
ROCKER ACTUATOR DETAIL
INDICATE "ON" (VISI-ON)
1.394 [35.41]
.370 [9.40] MAX.
±.020
[±.508]
1.530 [38.86]
±.020
[±.508]
1.304 [33.12]
OFF
.970 [24.64]
1.560 [39.62]
ON
1.375 [34.93]
1.125 [28.58]
.400 [10.16]
.100 [2.54]
LINE
LOAD
.625 [15.88]
INDICATE "OFF" (VISI-OFF)
& SINGLE COLOR
ON
OFF
ROCKERGUARD CONFIGURATION
LOAD
LINE
±.020 ±.508
.675 [17.14]
±.020 ±.508
.305 [7.75]
ON
±.020 ±.508
1.050 [26.67]
OFF
PANEL CUT - OUT DETAIL (ROCKER)
DOUBLE POLE
DIM. A
PANEL
THICKNESS
DIM. A
+.005 +.13
-.000 -.00
.062 [1.57] 1.385 [35.18]
.093 [2.36] 1.420 [36.07]
±.005 ±.13
1.139 [33.76]
.125 [3.18] 1.460 [37.08]
LOAD
LINE
Notes:
1 ALL DIMENSIONS ARE IN INCHES [MILLIMETERS].
2 TOLERANCE ±.010 [.25] UNLESS OTHERWISE SPECIFIED.
3 DIMENSIONS APPLY TO BOTH ROCKER STYLES.
4 I-O, ON-OFF OR DUAL LEGENDS AVAILABLE FOR VERTICAL OR HORIZONTAL MOUNTING.
5 NOTICE THAT CIRCUIT BREAKER LINE AND LOAD TERMINAL ORIENTATION ON INDICATE “OFF” IS OPPOSITE THAT OF INDICATE “ON”.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
NOTE
1. A
2. T
3. D
4. I-
V
5. N
O
IN