English
Language : 

HCPL-1930 Datasheet, PDF (1/13 Pages) Agilent(Hewlett-Packard) – Dual Channel Line Receiver Dual Channel Line Receiver Dual Channel Line Receiver
HCPL-1930, HCPL-1931, HCPL-193K,
5962-89572 1
Dual-Channel Line Receiver Hermetically Sealed
Optocoupler
Data Sheet
Description
The HCPL-193x devices are dual-channel, hermetically sealed,
high CMR, line receiver optocouplers. The products are capable
of operation and storage over the full military temperature
range and can be purchased as either a commercial product or
with full MIL-PRF-38534 Class Level H or K testing, or from the
DLA Standard Microcircuit Drawing (SMD) 5962-89572. This
16-pin DIP may be purchased with a variety of lead bend and
plating options. See Selection Guide — Lead Configuration
Options for details. Standard Microcircuit Drawing (SMD) parts
are available for each lead style.
CAUTION
It is advised that normal static precautions be
taken in handling and assembly of this
component to prevent damage and/or
degradation which may be induced by ESD.
Features
 Dual marked with device part number and DLA Standard
Microcircuit Drawing (SMD)
 Manufactured and tested on a MIL-PRF-38534 certified line
 QML-38534, Class H and Class K
 Hermetically sealed 16-pin dual in-line package
 Performance guaranteed over full military temperature
range: –55° C to +125° C
 High speed: 10 Mb/s
 Accepts a broad range of drive conditions
 Adaptive line termination included
 Internal shield provides excellent common mode rejection
 External base lead allows LED Peaking and LED current
adjustment
 1500 Vdc withstand test voltage
 High radiation immunity
 HCPL-2602 function compatibility
 Reliability data available
Applications
 Military and space
 High reliability systems
 Isolated line receiver
 Simplex/multiplex data transmission
 Computer-peripheral interface
 Microprocessor system interface
 Harsh environmental environments
 Digital isolation for A/D, D/A conversion
 Current sensing
 Instrument input/output isolation
 Ground loop elimination
 Pulse transformer replacement
1. See Selection Guide — Lead Configuration Options for available
extensions.
Broadcom
-1-