NON-ISOLATED DC/DC CONVERTERS
3 Vdc – 14.4 Vdc Input, 0.6 Vdc - 5.5 Vdc /3 A Outputs
Mar. 16, 2012
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Output Specifications (continued)
Parameter
Min
Typ
Line Regulation
VO ≥ 2.5V
-
-
VO < 2.5V
-
-
Temperature Regulation
-
-
Ripple and Noise (pk-pk)
-
50
Ripple and Noise (rms)
-
20
Output Short-Circuit Current
-
0.5
Output Capacitance1
ESR≥ 1 mΩ 10
-
ESR≥0.15 mΩ 10
-
ESR≥ 10 mΩ 10
-
Output Current
Output Current Limit
Inception
0
-
-
200
Output voltage overshoot
-
-
Turn-On Delay Times
(VIN=VIN, nom, IO=IO, max , VO to
within ±1% of steady state)
Output voltage Rise time
-
4
-
4.8
-
2.8
Max
Unit
Notes
0.4
%Vo,set VIN=VIN, min to VIN, max
5
mV
0.4
%Vo,set Tref=TA, min to TA, max
100
mV
5Hz to 20MHz BW, VIN=VIN, nom and IO=IO, min to
38
mV
IO, max, Co = 0.1μF // 22 μF ceramic capacitors)
-
A
Vo≤250mV, Hiccup Mode
22
TBD
TBD
3
-
3.0
-
-
-
μF
μF
μF
A
% Io,max
%Vo, set.
msec
msec
msec
Without the Tunable LoopTM
With the Tunable LoopTM
With the Tunable LoopTM
In either sink or source mode
1. Hiccup Mode
2.Current limit does not operate in sink mode
Vin = Vin,min to Vin, max,IO = IO, min to IO, max,
TA=25°C
With or without maximum external capacitance
Case 1: On/Off input is enabled and then input power
is applied(delay from instant at which VIN = VIN,
min until Vo = 10% of Vo, set )
Case 2: Input power is applied for at least one second
and then the On/Off input is enabled(delay from
instant at which Von/Off is enabled until Vo = 10% of
Vo, set)
Time for Vo to rise from
10% of Vo, set to 90% of Vo, set.
Notes: 1 External capacitors may require using the new Tunable LoopTM feature to ensure that the module is stable as well
as getting the best transient response. See the Tunable LoopTM section for details.
General Specifications
Parameter
Min
Typ
Efficiency
Vo=0.6V(8Vin) -
75.0
Vo=1.2V -
82.8
Vo=1.8V -
88.2
Vo=2.5V -
89.9
Vo=3.3V -
91.6
Vo=5.0V -
93.9
Switching Frequency
-
600
Input Undervoltage Lockout
Max
-
-
-
-
-
-
-
Unit
%
%
%
%
%
%
kHz
Notes
Vin= 12Vdc, TA=25°C
Io=Io, max , Vo= Vo,set
Turn-on Threshold
-
Turn-off Threshold
-
Hysteresis
-
Over Temperature Protection
-
-
2.69
0.2
TBD
3.0
V
-
V
-
V
-
C
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com