SLAN-03D2A0 Datasheet, PDF (18/25 Pages) Bel Fuse Inc. – NON-ISOLATED DC/DC CONVERTERS
NON-ISOLATED DC/DC CONVERTERS
3 Vdc – 14.4 Vdc Input, 0.6 Vdc - 5.5 Vdc /3 A Outputs
Mar. 16, 2012
Tunable LoopTM(continued)
Table 3
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Vo
5V
3.3V 2.5V 1.8V 1.2V 0.6V
Co
RTUNE
CTUNE
V
1x47F
1x47F
2x47F
1x330F 1x330F 2x330F
Polymer Polymer Polymer
270
1500pF
68mV
220
1800pF
60mV
180
3300pF
37mV
180
8200pF
18mV
180
8200pF
18mV
180
33nF
10mV
Recommended values of RTUNE and CTUNE to obtain transient deviation of 2% of Vout for a 1.5A step load with
Vin=12V.
Note: The capacitors used in the Tunable Loop tables are 47 μF/3 mΩ ESR ceramic and 330 μF/12 mΩ ESR
polymer capacitors.
Thermal Consideration
Power modules operate in a variety of thermal environments; however, sufficient cooling should always be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow, module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The
thermal data presented here is based on physical measurements taken in a wind tunnel. The test set-up is
shown in Figure 46. The preferred airflow direction for the module is in Figure 47.
Figure 46
Wind Tunnel
25.4_
(1.0)
PWBs
Power Module
76.2_
(3.0)
x
12.7_
(0.50)
Air
flow
Probe Location
for measuring
airflow and
ambient
temperature
Thermal Test Setup
The thermal reference points, Tref used in the specifications are also shown in Figure 47. For reliable operation
the temperatures at these points should not exceed 120oC. The output power of the module should not exceed
the rated power of the module (Vo,set x Io,max).
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com