English
Language : 

L06036R8CGSTR Datasheet, PDF (2/5 Pages) AVX Corporation – SMD High-Q RF Inductor
Accu-L® 0603 and 0805
SMD High-Q RF Inductor
HOW TO ORDER
L
0805
4R7
D
E
S
TR
Product
Inductor
Size
0603
0805
Not RoHS Compliant
Inductance
Expressed in nH
(2 significant digits +
number of zeros)
for
values <10nH,
letter R denotes
decimal point.
Example:
Tolerance
for
L ≤ 4.7nH,
B = ±0.1nH
C = ±0.2nH
D = ±0.5nH
4.7nH<L<10nH,
C = ±0.2nH
Specification
Code
E = Accu-L® 0805
technology
G = Accu-L® 0603
technology
Termination
Code
W = Nickel/
solder coated
(Sn 63, Pb 37)
**S = Nickel/
Lead Free
Solder coated
(Sn100)
Packaging
Code
TR = Tape and Reel
(3,000/reel)
22nH = 220
D = ±0.5nH
4.7nH = 4R7
L ≥ 10nH,
**RoHS compliant
2
G = ±2%
LEAD-FREE COMPATIBLE
COMPONENT
For RoHS compliant products,
J = ±5%
Engineering Kits Available
see pages 90-91
please select correct termination style.
ELECTRICAL SPECIFICATIONS TABLE FOR ACCU-L® 0603
Inductance
L (nH)
1.2
1.5
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10.0
12.0
15.0
450 MHz
Test Frequency
Available
Inductance Tolerance
±0.1, ±0.2nH
±0.1, ±0.2nH
±0.1, ±0.2nH
±0.1, ±0.2nH
±0.1, ±0.2nH
±0.1, ±0.2, ±0.5nH
±0.1, ±0.2, ±0.5nH
±0.1, ±0.2, ±0.5nH
±0.2, ±0.5nH
±0.2, ±0.5nH
±0.2, ±0.5nH
±2%, ±5%
±2%, ±5%
±2%, ±5%
Q
Typical
49
26
20
20
21
24
25
23
26
23
23
28
28
28
900 MHz
Test Frequency
L (nH)
Q
Typical
1.2
70
1.54
39
1.74
30
2.2
30
2.7
30
3.33
35
3.9
57
4.68
32
5.65
36
6.9
33
8.4
31
10
39
13.2
38
16.2
38
1900 MHz
Test Frequency
L (nH)
Q
Typical
1.2
134
1.52
63
1.73
50
2.24
49
2.75
48
3.39
56
4.06
60
4.92
46
5.94
54
7.3
47
10
35
11.8
47
14.1
30
25.9
30
2400 MHz
Test Frequency
L (nH)
Q
Typical
1.2
170
1.52
76
1.72
59
2.24
56
2.79
54
3.47
64
4.21
69
5.2
49
6.23
60
8.1
39
12.1
31
14.1
41
17.2
20
49.8
15
SRF min
(MHz)
10000
10000
10000
10000
9000
8400
6500
5500
5000
4500
3800
3500
3000
2500
RDC max
(Ω)
0.04
0.06
0.07
0.08
0.08
0.08
0.12
0.15
0.25
0.30
0.35
0.45
0.50
0.60
IDC max
(mA)
(1)
1000
1000
1000
1000
750
750
500
500
300
300
300
300
300
300
(1) IDC measured for 15°C rise at 25°C ambient temperature when soldered to FR-4 board.
Inductance and Q measured on Agilent 4291B / 4287 using the 16196A test fixture.
ELECTRICAL SPECIFICATIONS TABLE FOR ACCU-L® 0805
Inductance
L (nH)
1.2
1.5
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10
12
15
18
22
450 MHz
Test Frequency
Available
Inductance Tolerance
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.5nH
±0.5nH
±0.5nH
±2%, ±5%
±2%, ±5%
±2%, ±5%
±2%, ±5%
±2%, ±5%
Q
Typical
60
50
50
42
42
38
27
43
50
43
43
46
40
36
30
36
900 MHz
Test Frequency
L (nH)
Q
Typical
1.2
92
1.5
74
1.8
72
2.2
62
2.7
62
3.3
46
3.9
36
4.8
62
5.7
68
7.0
62
8.5
56
10.6
60
12.9
50
16.7
46
21.9
27
27.5
33
1700 MHz
Test Frequency
L (nH)
Q
Typical
1.2 122
1.5 102
1.8
88
2.2
82
2.8
80
3.4
48
4.0
38
5.3
76
6.3
73
7.7
71
10.0
55
13.4
52
17.3
40
27
23
–
–
–
–
2400 MHz
Test Frequency
L (nH)
Q
Typical
1.2
92
1.5
84
1.9
73
2.3
72
2.9
70
3.5
57
4.1
42
5.8
60
7.6
62
9.4
50
15.2
32
–
–
–
–
–
–
–
–
–
–
SRF min
(MHz)
10000
10000
10000
10000
10000
10000
10000
5500
4600
4500
3500
2500
2400
2200
1700
1400
RDC max
(Ω)
0.05
0.05
0.06
0.07
0.08
0.11
0.20
0.10
0.10
0.11
0.12
0.13
0.20
0.20
0.35
0.40
IDC max
(mA)
ΔT = 15°C ΔT = 70°C
(1)
(2)
1000
2000
1000
2000
1000
2000
1000
2000
1000
2000
750
1500
750
1500
750
1500
750
1500
750
1500
750
1500
750
1500
750
1500
750
1000
500
1000
500
1000
(1) IDC measured for 15°C rise at 25°C ambient temperature
(2) IDC measured for 70°C rise at 25°C ambient temperature
L, Q, SRF measured on HP 4291A, Boonton 34A and Wiltron 360
Vector Analyzer, RDC measured on Keithley 580 micro-ohmmeter.
29