English
Language : 

HCPL-4504-500E Datasheet, PDF (9/19 Pages) AVAGO TECHNOLOGIES LIMITED – High CMR, High Speed Optocouplers
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
Description
Installation classification per
DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤150 V rms
for rated mains voltage ≤300 V rms
for rated mains voltage ≤450 V rms
for rated mains voltage ≤600 V rms
for rated mains voltage ≤1000 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production
Test with tm = 1 sec,
Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
VIORM x 1.5 = VPR, Type and Sample
Test, tm = 60 sec,
Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
Safety Limiting Values - Maximum
Values Allowed in the Event of a Failure,
also see Thermal Derating curve
Case Temperature
Input Current
Output Power
Insulation Resistance at TS,
VIO = 500 V
Symbol
VIORM
VPR
VPR
VIOTM
TS
IS,INPUT
PS,OUTPUT
RS
HCPL-0454
OPTION 060
I-IV
I-III
55/100/21
2
560
1050
840
4000
150
150
600
≥109
HCPL-4504
OPTION 060
I-IV
I-IV
I-III
55/100/21
2
630
1181
945
6000
175
230
600
≥109
HCPL-J454
I-IV
I-IV
I-III
I-III
55/100/21
2
891
1670
1336
6000
175
400
600
≥109
HCNW4504
I-IV
I-IV
I-IV
I-IV
I-III
55/85/21
2
1414
2652
2121
8000
150
400
700
≥109
Unit
V peak
V peak
V peak
V peak
°C
mA
mW
Ω
*Refer to the optocoupler section of the Designer's Catalog, under regulatory information (IEC/EN/DIN EN 60747-5-2) for a detailed description of
Method a and Method b partial discharge test profiles.
NOTE: These optocouplers are suitable for "safe electrical isolation" only within the safety limit data. Maintenance of the safety data shall be ensured
by means of protective circuits.
NOTE: Insulation Characteristics are per IEC/EN/DIN EN 60747-5-2.
NOTE: Surface mount classification is Class A in accordance with CECC 00802.
9