Switching Specifications
For 0°C ≤ T ≤ 70°C, 4.5 V ≤ V ≤ 20 V, V = 0.8 V, all typicals at T = 25°C and V = 5 V unless otherwise noted. See note 13.
A
CC
E
A
CC
Parameter
Symbol Min. Typ. Max. Units Test Conditions
Fig. Note
Propagation Delay Time
t
PLH
to Logic High Output Level
Propagation Delay Time
t
PHL
to Logic Low Output Level
0.23
1.6 μs V = 0 V,
E
C = 15 pF
L
0.17
1.0 μs V = 0 V,
E
C = 15 pF
L
8, 9, 7
10
8, 9, 8
10
Propagation Delay Time
t -t
60
PLH PHL
Skew
ns I = 20 mA,
8, 9,
I
CL = 15 pF
10
Output Enable Time to
tPZL
Logic Low Level
25
ns II = 0 mA,
12, 13,
C = 15 pF
15
L
Output Enable Time to
t
PZH
Logic High Level
28
ns I = 20 mA,
12, 13,
I
C = 15 pF
14
L
Output Disable Time to
t
PLZ
Logic Low Level
60
ns I = 0 mA,
12, 13,
I
C = 15 pF
15
L
Output Disable Time to
t
PHZ
Logic High Level
105
ns I = 20 mA,
12, 13,
I
C = 15 pF
14
L
Output Rise Time
(10-90%)
Output Fall Time
(90-10%)
t
55
ns V = 5 V,
8, 9, 9
r
CC
C = 15 pF
11
L
t
15
ns V = 5 V,
8, 9, 10
f
CC
C = 15 pF
11
L
Common Mode Transient
Immunity at Logic High
Output Level
|CM |
H
1,000 10,000
V/μs V = 50 V (peak)
CM
I = 12 mA,
I
T = 25°C
A
16
11
Common Mode Transient
Immunity at Logic Low
Output Level
|CM |
L
1,000 10,000
V/μs V = 50 V (peak)
CM
I = 3 mA,
I
T = 25°C
A
16
12
Package Characteristics
For 0°C ≤ T ≤ 70°C, unless otherwise specified. All typicals at T = 25°C.
A
A
Parameter
Symbol Min. Typ. Max. Units
Input-Output Momentary
Withstand Voltage*
V
3750
ISO
V rms
Resistance, Input-Output
R
I-O
Capacitance, Input-Output
C
I-O
1012
ohms
1.0
pF
Test Conditions
RH ≤ 50%, t = 1 min,
T = 25°C
A
V = 500 V dc
I-O
f = 1 MHz, V = 0 V
I-O
Fig. Notes
6, 14
6
6
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous volt-
age rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your equipment
level safety specification, or Avago Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
7