English
Language : 

ACCL-9410 Datasheet, PDF (4/9 Pages) AVAGO TECHNOLOGIES LIMITED – Output enable function
ACCL-9410
Data Sheet
Insulation and Safety Related Specifications
Insulation and Safety Related Specifications
Parameter
Minimum External Air Gap
(Clearance)
Minimum External Tracking
(Creepage)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
Symbol
L(101)
L(102)
CTI
ACCL-9410
4.0
4.0
400
II
Units
mm
mm
Volts
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Measured from input terminals to output terminals,
shortest distance path along body.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Absolute Maximum Ratings
Parameter
Storage Temperature
Operating Temperature
Supply Voltage
Input Voltage
Output Voltage
Average Output Current
Symbol
Min
TS
-55
TA
-40
VDD1, VDD2
0
VI
-0.5
VO
-0.5
IO
Max
125
125
6
VDD + 0.5
VDD + 0.5
15
Units
°C
°C
V
V
V
mA
Recommended Operating Conditions
Parameter
Operating Temperature
Supply Voltage (3.3V)
Supply Voltage (5V)
Logic High Input Voltage
Logic Low Input Voltage
Symbol
Min
TA
-40
VDD1, VDD2
3.15
VDD1, VDD2
4.5
VIH
2
VIL
0
Max
Units
125
°C
3.6
V
5.5
V
VDD
V
0.8
V
Avago Technologies
-4-