English
Language : 

HCPL-063A-000E Datasheet, PDF (13/17 Pages) AVAGO TECHNOLOGIES LIMITED – HCMOS Compatible, High CMR, 10 MBd Optocouplers
PULSE GEN.
Z O = 50 Ω
tf = tr = 5 ns
INPUT VE
MONITORING NODE
HCPL-261A/261N
1
VCC 8
3.5 mA
IF
2
7
3
6
4
5
GND
+5 V
0.1 µF
BYPASS
*C L
RL
OUTPUT VO
MONITORING
NODE
*CL IS APPROXIMATELY 15 pF WHICH INCLUDES
PROBE AND STRAY WIRING CAPACITANCE.
INPUT
VE
OUTPUT
VO
t EHL
t ELH
3.0 V
1.5 V
1.5 V
120
VCC = 5 V
VEH = 3 V
VEL = 0 V
90 IF = 3.5 mA
tELH, RL = 4 kΩ
60
tELH, RL = 1 kΩ
30
tELH, RL = 350 Ω
tEHL, RL = 350 Ω, 1k Ω, 4 kΩ
0
-60 -40 -20 0 20 40 60 80 100
TA – TEMPERATURE – C
Figure 15. Test circuit for tEHL and tELH.
Figure 16. Typical enable propaga­tion delay vs. temperature.
HCPL-261A/-261N/-061A/-061N Only.
VCM
IF
A
B
VFF
HCPL-261A/261N
1
VCC 8
2
7
3
6
4
GND 5
+5 V
0.1 µF
BYPASS
350 Ω
OUTPUT VO
MONITORING
NODE
PULSE GEN. +
_
O Z = 50 Ω
VCM
0V
5V
VO
VO 0.5 V
VCM (PEAK)
SWITCH AT A: IF = 0 mA
VO (min.)
SWITCH AT B: IF = 3.5 mA
VO (max.)
CM H
CM L
HCPL-261A/261N OPTION 060 ONLY
800
PS (mW)
700
IS (mA)
600
500
400
300
200
100
0
0 25 50 75 100 125 150 175 200
TS – CASE TEMPERATURE – C
Figure 17. Test circuit for common mode transient immunity and typical waveforms. Figure 18. Thermal derating curve, dependence of safety limiting
value with case temperature per IEC/EN/DIN EN 60747-5-5.
13